Skip to main content
The search found 1204 results
Last Updated Fri, 04/18/2025 - 19:10
FAQ
… as diversion systems to allow liquid hydrogen to spill and boil off in a safe area. Care needs to be taken that … … 921 … 893 … Are remote impoundment basins required for liquid hydrogen facilities like those used for LNG facilities? … Liquid hydrogen facilities typically …
Last Updated Tue, 12/24/2024 - 21:59
Safety Culture Case Studies
… A new Process Safety coordinator attended a Process Hazards Analysis (PHA) revalidation shortly after she started … engineer who had worked at the facility a long time and led many of the facility’s PHAs. She discovered that many … learned this was way PHAs were performed at the facility for years, and none of the many auditors and government …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… An explosion and fire occurred at a reciprocating recycle … gas contained 9000 ppm of H2S (hydrogen sulfide) and the pressure was at 940 psig (65 bar). The failure of retaining … to prevent sulfide stress cracking) and inadequate design for the service. The manufacturer did not comply with the …
Last Updated Thu, 01/15/2015 - 22:48
Lesson Learned
… Sulfur Deprivation Test - Vessel Failure …
Last Updated Fri, 01/16/2015 - 19:22
Lesson Learned
… Hydrogen Purge Frequency Exceeded in Vessel
Last Updated Mon, 01/27/2025 - 23:30
Best Practice
… Gas Vessel Documentation, Tagging, and Labeling …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… The fire ignited roofing materials which had fallen down as the result of the explosion.The operator, who was outside the plant when the … was raised by the Gatekeeper who had heard the explosion and seen flames and smoke in the vicinity of the hydrogen …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… The explosion occurred while restarting the ammonia reactor. … the turbo-compressor. The explosion was followed by a jet fire. The hydrogen detectors and fire alarm notified the control room, triggering …
Last Updated Fri, 02/21/2025 - 22:53
Lesson Learned
… Hydrogen Tube Trailer Burst Disc Ruptures Prematurely While Filling …
Last Updated Thu, 05/30/2024 - 03:04
Basic page
… Key: = No Ignition = Explosion = Fire Hydrogen Incident Summaries by Equipment and Primary Cause/Issue Equipment / Cause Equipment Design or … 1/19/2009 8/6/2004 12/31/1969   1/1/1974 12/17/2004 Pressure Relief Device 7/25/2013 5/4/2012 1/15/2002 1/08/2007 …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… Hydrogen release and explosion due to a leak in a high pressure hydrogen …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… An explosion and fire occurred on a reformer at a fertiliser plant. Source of ignition was autoignition or electric motor. … Explosion and Fire on Reformer at Fertilizer Plant (599) …
Last Updated Wed, 01/14/2015 - 22:50
Lesson Learned
Last Updated Fri, 01/16/2015 - 18:30
Lesson Learned
… Organic Vapor Ignites When Hydride Decomposes in Air …
Last Updated Wed, 07/09/2025 - 15:39
FAQ
… very hazardous. Subsequent ignition resulted in internal pressure that exceeded the limits of the storage system. The … of oxygen within the hydrogen system is important for safe operation. … 806 … 2106 … 2094 … What were the causes of the 2019 explosion at the Korean research facility involving an …
Last Updated Fri, 10/18/2024 - 20:33
Fuel Cell Codes and Standards
… This publication is an industry-wide guideline for in-service mechanical integrity of PSA units and is intended to contribute to the operational safety and … is focused on the parts of the PSA that are subjected to pressure cycles, although some consideration is given to the …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… ignited. A fireball was formed followed immediately by an explosion. The Vapour Cloud explosion VCE (mainly negative overpressure) caused … the surrounding buildings (walls, doors, roofs). The over-pressure was estimated at 0.035 bar to 45 m and the amount of …
Last Updated Wed, 04/23/2025 - 18:26
Document Library
… Ltd. (Daewoo) performed vented (i.e., partially-confined) vapor cloud explosion (VCE) tests with both propane and lean … blast waves that are representative of VCEs suitable for blast loading test articles, but has also been used for
Last Updated Mon, 11/11/2024 - 19:17
Best Practice
… Hazard Analysis and Risk Assessment …
Last Updated Fri, 01/16/2015 - 19:59
Lesson Learned
… Hydrogen-Oxygen Balloon Hazards
We are professional and reliable provider since we offer customers the most powerful and beautiful themes. Besides, we always catch the latest technology and adapt to follow world’s new trends to deliver the best themes to the market.

Contact info

We are the leaders in the building industries and factories. We're word wide. We never give up on the challenges.

Recent Posts