Skip to main content

Risks Incurred By Hydrogen Escaping From Containers and Conduits

Type of Publication
Year of Publication
1998
Authors
M.R. Swain; E.S. Grilliot; M.N. Swain
Abstract

This paper is a discussion of a method for hydrogen leak classification. Leaks are classified as; gas escapes into enclosed spaces, gas escapes into partially enclosed spaces (vented), and gas escapes into unenclosed spaces. Each of the three enclosure classifications is further divided into two subclasses; total volume of hydrogen escaped and flow rate of escaping hydrogen. A method to aid in risk assessment determination in partially enclosed spaces is proposed and verified for several enclosure geometries. Examples are discussed for additional enclosure geometries.

Volume
2
Notes

OSTI as DE98007508

Pagination
787-803
Number
0