Skip to main content

HIAD Sources Categories: ARIA


The fire occurred after a hydrogen released from a venting valve opened for inspection. The hydrogen was at 300 bar and 300C centigrade. The hydrogen ignited probably spontaneously and killed 4…
A hydrogen leak occurred on the hydrogen line of a hydro-desulfurization unit, followed by ignition . The failure was located on a supply manifold of the unit at a support beam. The unit was shut…
Hydrogen leaked from an analyser and ignited .On-site staff isolate the leak. As the leak was very quickly isolated, the amount of hydrogen released was negligible. Event no. 35501 of the French…
The hydrogen jet fire a pipe have been detected by a night operator which was making rounds in a solvent production unit. The unit's emergency response team managed the fire in minutes. Operators…
A detonation was heard and the hydrogen supply of the site was automatically shut down by the safety devices.The fire was caused by a hydrogen leak and led to the formation of a fireball at the end…
The fire occurred around 13:20 on three cells of the chlorine manufacturing unit. A leak of hydrogen in the electrolysis room was at the origin of the fire; the ignition of the H2 cloud caused a…
The fire occurred on a flange of a hydrogen supply line to a desulfurization reactor unit of diesel, which leaked and ignited (30 cm flame) The leak was stopped by isolating the part of line…
A hot oil line (8-inch) in the hydro-desulfurisation (HDS) unit failed due to fatigue cracking. Hot oil at 50 bar and 343C sprayed across the roadway into the hydrogen units where ignition occurred.…
A hydrogen jet fire occurred on a 25m3 tank while transferring a catalyst to a buffer tank. The constabulary created an area of safety around the plant while the staff extinguishes the fire by…
Hydrogen leaked from the hydrogen compressor and ignited. The compressor was part of the desulfurization unit of a refinery. It had just been delivered and was under commissioning testing. The fire…
The release occurred on a pipeline inside a steam cracking unit located between two hydrogenation units. The gaseous mixture transported through this line (2" diameter, 30 bar, 40C) was composed of…
A hydrogen leak occurs in a manufacture of steel pipes. The leak is detected and the alarm is triggered.
The leak occurred at the hydro-isomerisation unit of a refinery. Following the observation of a pressure drop between two heat exchangers, controls were carried out on site. A noise was heard, but no…
A hydrogen leak occurred in in the cooling system of electricity generation part of the in a nuclear power plant. .
In a hydrodesulfurization unit of a refinery, a leak on a hydrogen line ignited and damaged the surrounding lines, including one with acid gas. The weather conditions (fog and very little wind)…
An explosion occurred on a unit producing hydrogen for the nearby refinery.The following fire was extinguished in 10 minutes by the public service fire brigade. Two workers were lightly injured.
The event occurred in a desulfurisation unit for heavy oil (hydro-cracking, Isomax process). The hydrogen release took place from one of the heat exchanges, after the restart of the unit. The reason…
A violent explosion occurred in a refinery's crude oil hydrodesulfurization unit. The unit's alarm is immediately triggered in the control room, the operator activates the internal emergency plan.…
Hydrogen leaked and ignited on a cell in the sodium chlorate (NaClO3) workshop of a chlorinated products plant.There were no victims and no damage to the environment. On-site firefighters controlled…
A pallet containing 9 hydrogen cylinders is damaged during the operation of unloading the cylinders trailer by means of a forklift. A 2 mm wide crack, caused by the fork, is observed on a flexible.…