Skip to main content
The search found 2580 results
Last Updated Fri, 05/24/2024 - 23:46
Bibliography Entry
… the need to understand requirements to safe blow-down of hydrogen onboard storage tanks through a pressure relief … ventilation. Current composite tanks for high pressure hydrogen storage have been shown to rupture in 3.5-6.5 min in … a large PRD venting area is currently used to release hydrogen from the tank before its catastrophic failure. …
Last Updated Sat, 11/04/2017 - 04:27
Bibliography Entry
… The FEM computed results on the stress safety of 70MPa hydrogen gas tank were compared with a criterion of a stress … 31mm, 10.2mm . … On the Optimized Design of a Composite Hydrogen Fuel Tank using Taguchi Method …
Last Updated Fri, 05/24/2024 - 23:46
Bibliography Entry
… Due to rapid growth in the use of hydrogen powered fuel cell forklifts within warehouse … scientific methods that support the creation of new hydrogen safety codes and standards for indoor refueling … used to analyze potential consequences from ignited hydrogen leaks in facilities certified according to existing …
Last Updated Sat, 11/04/2017 - 04:27
Bibliography Entry
… a study on the safety of bulk transport and storage of hydrogen as a fuel, carried out by the Health and Safety … and data required to develop fully a risk assessment for a hydrogen delivery and storage infrastructure. The methodology … current UK LPG consumption, comparisons were made between hydrogen and LPG for mode of failures and number of trips …
Last Updated Fri, 05/24/2024 - 23:46
Bibliography Entry
… being paid by car manufacturers and the general public to hydrogen as a middle and longterm energy carrier for … 6th frame-work program of the EU will be shown. … 1085 … Hydrogen Onboard Storage - An Insertion of the Probabilistic …
Last Updated Fri, 05/24/2024 - 23:46
Bibliography Entry
… propagation, acceleration and transition to detonation in hydrogen-airmixture in 2 m long rectangular cross section … bottom wallwas performed. The initial conditions of the hydrogen-air mixture were 0.1 MPa and 293 K. Threedifferent … … 1085 … Fast Turbulent Deflagration and DDT of Hydrogen-Air Mixtures in Small Obstructed Channel-Paper …
Last Updated Sat, 11/04/2017 - 04:27
Bibliography Entry
… Protection and Nuclear Safety (IRSN) are developing a hydrogen risk analysis code, called the TONUS code, which … case. The TONUS CFD code is presently used to support the hydrogen risk assessment for the European Pressurized Reactor … and to investigate the impact of the two-room concept on hydrogen distribution in the EPR containment. (c) 2007 …
Last Updated Wed, 11/20/2024 - 23:21
Document Library
… An under-expanded hydrogen jet from high-pressure equipment or storage tank is … the delayed ignition of a highly turbulent under-expanded hydrogen jet generates a blast wave able to harm people and … ignition and the follow-up deflagration or detonation of hydrogen jets at an any location from the jet, DPexp/P0, is …
Last Updated Tue, 03/03/2020 - 18:36
Bibliography Entry
… compressed natural gas (CNG) and later a blend of CNG and hydrogen. Of the other three vehicles, one was fueled with pure hydrogen and two were fueled with a blend of CNG and hydrogen. The three blended-fuel vehicles were originally …
Last Updated Sat, 11/09/2024 - 00:38
Best Practice
… Indoor Refueling of Hydrogen-Powered Industrial Trucks …
Last Updated Sat, 11/09/2024 - 00:01
Best Practice
… Small-Capacity Hydrogen Generators for Laboratory Use …
Last Updated Fri, 05/24/2024 - 23:46
Bibliography Entry
… storage system (unintended release) refueling … 1085 … Hydrogen Safety in Transportation: Industry Perspective (GM) …
Last Updated Fri, 05/24/2024 - 23:46
Bibliography Entry
… No Abstract Available … 1085 … A Rural Hydrogen Transportation Test Bed-Paper …
Last Updated Sat, 11/04/2017 - 04:27
Bibliography Entry
Hydrogen systems safety assessment and risk-reduction …
Last Updated Fri, 01/16/2015 - 19:51
Lesson Learned
… Improper Purging Procedure Results in Hydrogen Fire …
Last Updated Sat, 11/04/2017 - 04:27
Bibliography Entry
… CYTOLYSIS OF CORNEAL EPITHELIAL-CELLS BY HYDROGEN-PEROXIDE …
Last Updated Wed, 01/21/2015 - 19:39
Lesson Learned
… High-Density Hydrogen Storage Material Incident …
Last Updated Thu, 01/15/2015 - 20:21
Lesson Learned
Hydrogen Delivery Truck Roll Over Accident …
Last Updated Thu, 01/15/2015 - 20:32
Lesson Learned
Hydrogen Delivery Truck/ Facility Connection Mishap …
Last Updated Sat, 11/04/2017 - 04:27
Bibliography Entry
… … Passive Ventilation Systems for the Safe Use of Hydrogen