Last Updated Thu, 10/17/2024 - 18:36
Fuel Cell Codes and Standards
… Presents design guidelines for hydrogen vent systems for gaseous and liquid hydrogen installations at consumer sites, and provides …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… A leak occurred at a of a liquid withdrawal valve of a liquid hydrogen storage tank. The hydrogen escaped at the flange …
Last Updated Tue, 07/15/2025 - 15:03
FAQ
… in pressure due to the very large expansion ratio as the liquid converts to gas. Relief devices are required since the … LH2 is warmed, it undergoes a phase transformation from liquid to gas (progressively more bubbles until 100%) at a … The vaporization occurs within a closed system and only hydrogen is present. No air enters the system and the volume …
Last Updated Sat, 06/01/2024 - 07:34
Basic page
… This is a list of acronyms and terms used in the Hydrogen Analysis Resource Center. A full glossary of … fuel it takes to equal the energy content of one liquid gallon of gasoline. GM - General Motors Corporation … Airport Liquefied Hydrogen (LH 2 ) - hydrogen in liquid form. Hydrogen can exist in a liquid state, but only …
Last Updated Fri, 10/18/2024 - 15:37
Fuel Cell Codes and Standards
… and horizontal) intended for above ground storage of liquid hydrogen. This publication applies to liquid hydrogen storage tanks with maximum allowable working …
Last Updated Thu, 10/17/2024 - 18:37
Fuel Cell Codes and Standards
… the current commodity specification for gaseous and liquid hydrogen including hydrogen for fuel cell applications. The document also …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… equipment. The high pressure combustion took place in a liquid hydrogen tank (H2) under a high pressure and in presence of 12 m (700 kg) of liquid H2. The test was stopped as the malfunction was …
Last Updated Mon, 06/23/2025 - 16:09
FAQ
… The end use of hydrogen usually drives the cleaning for initial … Practice for Oxygen Cleaning of Valves & Fittings. For liquid hydrogen systems, the additional concern is with removing all substances that will be solid at liquid hydrogen temperatures. That includes all gases except …
Last Updated Wed, 07/16/2025 - 14:56
FAQ
… are no specific code resources that specifically cover hydrogen liquefaction plants, but they must be built to the … mechanical codes for process plants. Codes such as NFPA 2, Hydrogen Technologies Code, for installation and emergency … Process Safety provides guidance that is not specific to liquid hydrogen but instead addresses process safety. Other …
Last Updated Tue, 09/17/2024 - 00:37
Fuel Cell Codes and Standards
… stationary fuel cell devices / installations fuelled by hydrogen and ventilated outdoors. 2. Does not apply where the hydrogen fuel is made by internal / adjacent reforming of … prescribed below, the design, location and installation of hydrogen storage systems for fuel cells should comply with …
Last Updated Mon, 07/14/2025 - 16:30
FAQ
… materials. Estimated lifetimes are below in years: • Liquid Hydrogen Tanks: 15-20 years between refurbishment but … control Manifolds: 10-15 years • Cryogenic Liquid Pumps: 15-20 years but generally require annual …
Last Updated Mon, 06/23/2025 - 17:03
FAQ
… lights on a delivery truck) while delivering gaseous or liquid hydrogen? … Safety Hazards from Lights on Hydrogen Delivery Trucks …
Last Updated Tue, 07/15/2025 - 14:50
FAQ
… Vacuum jacketed piping is double walled and is used in liquid hydrogen service to provide insulation. While not equipped … … 2111 … 2089 … 2112 … Can double pipes be used for hydrogen leak detection? … Double pipes for hydrogen leak …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… pressure fluctuations in the lubricating oil system of a hydrogen compressor, the operator handled the situation … hydrogen-air explosion and a following fire, while diesel liquid spilled out to form a liquid pool on the ground. … Explosion and Fire at a Diesel …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… A fire broke out on the worlds first hydrogen carrier vessel shortly before setting sail from … the worlds first international shipment of liquefied hydrogen. A flame was seen coming from the gas combustion … during an attempt to burn excess boil-off gas from the liquid hydrogen cargo tank. … Hydrogen Release and Ignition …
Last Updated Thu, 06/19/2025 - 15:28
FAQ
… Gaseous hydrogen can be stored forever as long as the system integrity is maintained. However, liquid hydrogen is “use it or lose it” and will boil from … for a pump, but again, if usage is sufficient, then the liquid being removed from the tank can minimize or eliminate …
Last Updated Fri, 10/25/2024 - 19:50
Fuel Cell Codes and Standards
… Compressed gas Association to provide uniform values of liquid and gas density for atmospheric gases and hydrogen for the benefit of suppliers and users of these … … CGA P-6 Standard Density Data, Atmospheric Gases and Hydrogen …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… Atmel building and established a safe zone. The crews used liquid nitrogen. The biggest danger was the chance of explosion … Hazmat Crews Respond to Hydrogen Explosion Risk at Atmel Building (39) …
Last Updated Thu, 06/26/2025 - 16:59
FAQ
… is primarily due to: 1) large flows required to dilute hydrogen below the flammable range, 2) the cost of the … stack when being inserted a vent header/stack serving a liquid hydrogen system, 4) the potential for backpressure … deflagration. If a nitrogen purge is to be used on a liquid hydrogen system, then the vented hydrogen should have …
Last Updated Thu, 06/19/2025 - 15:43
FAQ
… The most common means to warm liquid or cold gaseous hydrogen is the use of ambient air vaporizers using ambient … vaporize H2 in an economizer circuit of an LH2 system? … Hydrogen Economizer and Vaporizer Media …