Minor car crash involving a FCEV, damaging its front bumper.No injury or harm was caused to the driver or anyone else.
During a filling at a hydrogen refuelling station, the station was shut down due to a gas detection. The leak was extremely small and difficult to locate but the gas was directed upwards towards the…
A motor scooter striped the left side of a hydrogen and fuel cells bus .
A motor scooter scratched the left side of a hydrogen bus
Motorway accident which involved a large quantity of vehicles and a gaseous tube trailer which transported gas hydrogen in pressure. Some cars were burning under the back part of the gaseous tube…
This near miss occurred at the at an airport's hydrogen refilling station. Around 4:30 a.m., the hydrogen detector of the station was triggered and a sound and light alarm were activated. The…
This near miss occurred at an airport's hydrogen refilling station. At 7:35, a hydrogen leak was detected by hearing whistles in the near of a pipe. The operators warned the airport firefighters ten…
A hydrogen pipe burst at a semiconductor plant injuring 1 person
A pipe rupture occurred in a steam condensing line of a residual heat removal system at the Hamaoka Nuclear Power Station Unit-1 (Hamaoka-1) during operation at rated power. The reactor was manually…
The vessel affected by the incident was a gas storage used for the desulfurisation process. The desulfurization gas had high hydrogen content. The vessels had cracks in the upper transverse fillet…
A hydrogen and fuel cells bus was hit by a private car, which was driving out from a parking place. Body damage on the rear, right side.
A private car did not observe the right of way and hit a hydrogen and fuel cells bus on the right side.
Private car not observing the right of way hit a hydrogen bus on the right side
The event occurred at the flanges on the outlet of a desulfurization reactor, which was working under about 300 degrees C The flanges and bolts were cooled down by a large amount of rainwater which…
Minor leak in the break-away coupling for 35MPa dispenser of a refuelling station for buses.The leak developed in the break-away coupling during a controlled test refuel. The test was attended by…
hydrogen gas released from vent stack following failure of relief valve in pressure relief system on bulk hydrogen installation, no ignition and no injuries.
Leak of hydrogen at a refinery which may have been caused by a faulty compressor.
A truck-trailer carrying compressed hydrogen cylinders stopped on an autobahn and reported a hydrogen leaking from the cylinders. The highway was immediately closed in both directions. When the fire…
Malfunctioning of the non-return valve of the hydrogen compressor has caused the pressure between the hydrogen bottle and the compressor to rise to the maximum allowed pressure of 275 barg. As a…
A factory was evacuated after a tank began leaking hydrogen. No injuries were reported