Skip to main content

HIAD Facility - Operational Condition: Normal


A hydrogen leak took place on a trailer carrying compressed hydrogen, located inside the fenced perimeter of a hydrogen station. According to the company managing the hydrogen delivery and refuelling…
The rupture disk installed on a liquid hydrogen tank failed, in a plant producing organic chemicals, during the weekly shut down. The hydrogen ignited at the exit of the exhaust chimney. The fire…
A liquid hydrogen leak occurs in a steel plant on a 42000 l tank of liquid hydrogen. A sealing coupling was installed to stop the leak.
A hydrogen feed line ruptured without igniting at an oil refinery.
The release occurred after the collision between a truck containing liquid hydrogen and a truck containing manganese dioxide on a highway.Due to the release, the traffic was interrupted for 4 hours…
A leak occurred on the safety valve of a train wagon transporting liquid hydrogen wagon. The train was composed of 10 wagons. The train was stopped on the railway several hours to allow…
Near the end of the process of filling a gaseous hydrogen tube trailer at a liquid hydrogen transfilling station, a safety pressure-relief device (PRD) rupture disc on one of the tube trailers ten…
A tractor-trailer carrying canisters of gaseous hydrogen gas crashed on a major East Coast route. Compressed hydrogen gas leaked from some of the containers after the truck rolled on its side.
The incident occurred in a plant producing organic chemistry products. Hydrogen leaked briefly from an hydraulic valve. There has been no victim.
A hydrogen leak alarm was received in the control room from the reformer of the hydrogen plant of a chemicals manufacturing facility. The reformed was depressurised and the leak stopped. The leak was…
An aerosol of hydrogen, hydrogen chloride and sulfuric acid is released in a plant producing chlorine via electrolysis.The exhaust pipe on the water circuit of the electrolyzer was blinded due to the…
The release took place in a metal cold rolling workshop.The hydrogen leaked from a cylinder of 15 m3, which was part of a storage system of 250 m3.Half of the workshop and the surrounding roads were…
A hydrogen release occurred in a storage area of a nuclear power plant.. The storage consisted of three trailers made of 14 compressed gas cylinders each. The cylinders, mounted horizontally, had a…
A hydrogen safety sensor went into alarm at a hydrogen demonstration facility. The early morning temperature was near freezing and there was a trace of precipitation on exposed surfaces. Upon further…
A leak occurred at a of a liquid withdrawal valve of a liquid hydrogen storage tank. The hydrogen escaped at the flange between the valve body and the upper part of the valve (flange with tongue and…
A hydrogen leak was reported at a chemical plant.
On February, 20, 1987, the Vogtle nuclear power plant reported a hydrogen leak inside the auxiliary building. This plant was recently licensed, had never been critical, and was in cold shutdown at…
An accident involving a truck hauling liquid hydrogen closed an interstate highway for two hours.
The incident occurred in the hydrogenation reactor and products cooling unit. The reactor operated under vacuum conditions and the cooling medium was water.Toxic, flammable and explosive substances (…
A hydrogen leak occurred on a flange located on a pipe coming from the hydrogen storage tank. The staff was confined and the Internal Operation Plan was launched.Helium was injected in the tank and…