Skip to main content

HIAD Event Initiating System: Hydrogen System Initiating Event


A process operator was working in the collaring/ decollaring area of a mechanical workshop. An electric cross cut saw was used to make two diagonal cuts in the collar of a hydrogen cylinder before…
An explosion occurred whole two employees inside a facility were working with aluminum paste. Crews believed the blast was caused by hydrogen that had built up in the plant.
Several explosions occurred in one of the catalytic reforming units of the refinery, followed by a fire in the same unit. The fire derived from the explosions lasted for almost one day. The…
The accident occurred in the Reactor 6 used to carry out the hydrogenation of a pharmaceutical intermediate.The operation of the plant was organized in two shifts. Since the hydrogenation at Reactor…
Workers were connecting a compressed hydrogen cylinder, when a release of hydrogen occurred within a safety-box for flammable gases. During the emergency response procedures, the explosive atmosphere…
Piping breakage at atomic power plant- Steam piping (inside diameter: 15 cm; thickness: 1.1 cm) of a heat exchanger for removing residual heat from a reactor was broken during the test of a high…
The failure of a high pressure hydrogen-based synthetic gas feed line to the ammonia converter produced a sudden explosion followed by a severe fire. One of the operators was fatally injured. The…
A tank of liquefied hydrogen felt down in a chemical plant.The tank, containing 100 m of liquid hydrogen, was installed on a concrete plate, which failed. The hydrogen started leaking from the valve…
The cracking happened in an ammonia plant, started up in 1970, on the pipe leading hot synthesis gas from the synthesis convertor to the first heat exchanger. This pipe was affected by six cracks and…
A dual phase hydrogen tanker was expected to refil the storage of arefulein gstation for buses. Due to the failure of the a bolt of the tanker pump, the fefeulling could not take place. This resulted…
FCEV frontal crash
Hydrogen gas leaking from drain pipes in a hydrodesulfurization plant: There was a hydrodesulfurisation plant which had a recycle hydrogen compressor fitted with a suction rectifier. Hydrogen gas…
During repairs of a heat exchanger in a benzene plant, a mixed gas (methane and hydrogen) contained in the cold box attached to the exchanger leaked and caught fire from a welding spark. The…
A ruptured hydrogen line caught fire at a commercial gas plant.
A fire in a leaking hydrogen unit at a 220,000-barrel oil sands plant temporarily cut production nearly 80 percent.
Fire due to hydrogen gas leakage from a cadre falling in transportation.
Leaking hydrogen ignited a fire that burned several hours at an oil refinery.
An operator had just replaced the ignition port cover on a hydrochloric acid plant burner. Normal start-up was continued by closing the drain valve in the product run off line and opening the…
The fire started as a result of an explosion in the process section of a refinery. An open structure of steelwork protected with reinforced concrete housed the usual furnaces, reactors, heat…
Fire and explosion in a chemicals plantThe process unit affected by the incident was a two-step production, consisting of i) hydrogenation of phenyl acetyl carbinol with benzyl amine in a isopropyl…