The laboratory works with soil bacteria that cannot survive in the presence of oxygen. As a result, research work is conducted inside a plastic chamber in which the chemical constituents in the air…
A potentially explosive situation was reported by safety inspectors at a nuclear waste tank. The waste slurry had formed a thick crust which was trapping hydrogen being continuously generated…
This near miss occurred at an airport's hydrogen refilling station. At 7:35, a hydrogen leak was detected by hearing whistles in the near of a pipe. The operators warned the airport firefighters ten…
The event occurred at the hydrogenation unit of a pharamceutical company. 145 kg of hydrogen were released the atmosphere at the gas circulation pump, due to a maintenance error . A…
A leak occurred on a line connecting the hot separator to the cold separator of a refinery diesel desulfurization. The alert was given by the activation of the fixed H2S detector. The 30 bar pressure…
Compressed hydrogen was released from a storage system due to the rupture of a Bourdon-type pressure gauge.
A road tanker was being loaded with liquid hydrogen from a 15,000 gallon storage tank, when fire broke out after 1 inch rupture disk failed, ignition source was a loose connection in down stream…
A hydrogen leak took place on a trailer carrying compressed hydrogen, located inside the fenced perimeter of a hydrogen station. According to the company managing the hydrogen delivery and refuelling…
The accidental hydrogen release occurred when testing the storage system connected to a PEM electrolyzer. The leak test consisted in filling the storage with hydrogen at step-wise increase of…
A six-cylinder rack containing an argon / hydrogen mixture is dropped from a truck on a national highway, causing a gas leak.A security perimeter was set up. The services of the equipment took care…
During the start-up of a propylene hydrogenation reactor, very high temperatures were generated in the catalyst bed. At the time, propylene and hydrogen were being fed to the reactor which contained…
The event occurred while re-starting the ammonia production unit after a technical stop, a synthesis gas (50% hydrogen, 17% ammonia, methane and nitrogen) leak ignited on a flange located just after…
Two hydrogen explosions occurred at a boiling water reactor (BWR). The first explosion occurred at 9:30 a.m. and was mostly confined to the off-gas system. Damage was relatively minor.The second…
Two hydrogen explosions occurred at a boiling water reactor (BWR). The first explosion occurred at 9:30 a.m. and was mostly confined to the off-gas system. Damage was relatively minor.The second…
At 17:30 on 5 may 2019, the pipeline operator was notified by a third party that there was a possible leak on its hydrogen pipeline, as identified by sound. Operator personnel arrived on the site at…
Fire of drums containing lithium metal powder: Spontaneous combustion took place at drums containing lithium metal powder which were charged with argon gas for experiments. While lithium metal powder…
Release from a welding of a hydrogen transmission pipeline At 12:45 pm the operation control centre (OCC) recognised that a customer flow and pressure dropped significantly. At 13:28 the OCC made the…