Skip to main content
The search found 1521 results
Last Updated Tue, 02/04/2025 - 13:06
Fuel Cell Codes and Standards
… GB/Z 34541-2017 Safety operation management regulation for hydrogen fueling facility of hydrogen vehicles …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… A fire started on the brakes of a truck carrying hydrogen. Due to the risk of extension of the fire to the hydrogen, the fire brigade install an emergency area until … the fire is extinguished.There has been no release of hydrogen. … Conventional Fire on a Hydrogen Carrier Truck …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… A pick-up truck pulling a trailer carrying compressed hydrogen crashed in Ohio yesterday. The hydrogen leaked and ignited, producing flames ten metres into the air. The hydrogen quantity transported was 450 kg. … A Fire After …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… according to HIAD validator]The explosion happened in two hydrogen tanks ('receivers') whcih were receiving and storing hydrogen produced by a water electrolyzer via two compressors. The hydrogen was then supplyed to a further non-specified …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… The hydrogen jet fire a pipe have been detected by a night … managed the fire in minutes. Operators stopped the flow of hydrogen by closing a valve. The hydrogen network was purged with nitrogen.The unit has three …
Last Updated Fri, 10/11/2024 - 18:43
Fuel Cell Codes and Standards
… for evaluating material compatibility with compressed hydrogen applications. The results of these tests are … materials performance in applications utilizing compressed hydrogen. This standard is not intended to replace sound … the design of a component manufactured for use in certain hydrogen applications. … Published August 2019.  Available …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
hydrogen gas released from vent stack following failure of relief valve in pressure relief system on bulk hydrogen installation, no ignition and no injuries. … Release from a Bulk Hydrogen Storage (324) …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… The fire occurred after a hydrogen released from a venting valve opened for inspection. The hydrogen was at 300 bar and 300C centigrade. The hydrogen ignited probably spontaneously and killed 4 workers …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… A leak occurred in a vehicle carrying 218 cylinders of hydrogen. The contents of 28 cylinders, 90 m of hydrogen, escaped. A security perimeter was set up with stop … the road and rail traffic. … Release During Transport of Hydrogen Cylinders (822) …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… a bus garage when carrying out the purging process of the hydrogen cylinders. This process was executed via an … instruction, but the valve did not start to evacuate hydrogen when expected. The fuel cell engineer tried to … The sealing O-ring of the tool was damaged and caused a hydrogen release in the vicinity of the manual override tool. …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… A truck-trailer carrying compressed hydrogen cylinders stopped on an autobahn and reported a hydrogen leaking from the cylinders. The highway was … left his vehicle. A pipe was reported to be leaking hydrogen. Fire-fighters closed a valve on the affexted …
Last Updated Fri, 04/18/2025 - 19:10
FAQ
… but as a precaution, any material that could be exposed to liquid air must be compatible for both oxygen and cryogenic … formation due to failure of the insulation on a liquefied hydrogen system and what measures can be taken to minimize …
Last Updated Mon, 11/04/2024 - 16:56
Fuel Cell Codes and Standards
… and environmental aspects of the performance of hydrogen generators described in ISO 16110-1 … Published in … a SA prefix.      Available at www.iso.org … ISO 16110-2 Hydrogen Generators Using Fuel Processing Technologies - Test …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… a power generator during the shutdown of one reactor unit. Hydrogen leaked from the cooling circuit of the generator due to damaged sealing. The hydrogen ignited. The fire was extinguished after 1 hour 40 minutes. … Hydrogen Fire on the Generator of a Power Plant (1043) …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
Hydrogen leak due to a fault with non-process related battery equipment.After reporting the hydrogen leak, fire crews have been called to a gas terminal. … related battery equipment. … Accidental Formation of Hydrogen from Batteries (1013) …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… generated in the catalyst bed. At the time, propylene and hydrogen were being fed to the reactor which contained a granular catalyst. The temperature rose rapidly, and the hydrogen supply valve tripped at 176 degrees C. Despite the … the incident was caused by wrongly setting the propylene/ hydrogen ratio as a result of faulty calibration of the flow …
Last Updated Wed, 04/23/2025 - 18:42
Document Library
… The Hydrogen Safety Panel was tasked with conducting work under the project “Hydrogen Safety Panel Review of Department of Energy’s Fuel … implemented by the project teams.    … Final Report: Hydrogen Safety Panel Review of DOE Fuel Cell Projects …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… A hydrogen leak was reported at a chemical plant. … Release of Hydrogen in a Chemicals Production Plant (125) …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… 3 workers were injured in the hydrogen explosion … Three Workers Injured in Hydrogen Explosion (53) …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… Fire due to hydrogen gas leakage. … Release from a Hydrogen Production Plant (593) …