Skip to main content
The search found 1559 results
Last Updated Fri, 04/18/2025 - 19:10
FAQ
…   … 882 … 895 … 804 … How much ventilation would a hydrogen compressor enclosure need in California, assuming …
Last Updated Tue, 07/01/2025 - 16:01
FAQ
… but then larger banks that contain larger quantity of hydrogen that will be released in a single event. The main … must be closed during transport), a smaller release of hydrogen would occur. … 945 … 892 … 2061 … There is an …
Last Updated Thu, 11/14/2024 - 16:29
Fuel Cell Codes and Standards
… technical requirements for the safe integration of gaseous hydrogen fueled Proton Exchange Membrane (PEM) Fuel Cell …
Last Updated Thu, 06/26/2025 - 16:14
FAQ
… For lightening refer to NFPA 780 and for grounding of the Hydrogen equipment, refer to NFPA 70 (Article 250 and Article …
Last Updated Mon, 06/23/2025 - 16:42
FAQ
… will likely point to compliance with NFPA 2/55 for the hydrogen and other gas supply systems, ASME Boiler and …
Last Updated Thu, 04/10/2025 - 16:07
Fuel Cell Codes and Standards
… (natural gas, liquefied petroleum gas, propane, butane, hydrogen etc.)  or liquid fuel (kerosene, methanol etc.); …
Last Updated Thu, 06/26/2025 - 16:56
FAQ
… There is no specific requirement not to vent liquid hydrogen from a vent system. Best practice would be to only …
Last Updated Thu, 07/11/2024 - 17:30
Calculator Tools
… to obtain the heating value of a given mass or volume of hydrogen or other fuels, or to calculate the mass or volume … Desired Output: Heating Values Fuel Amount Fuel: Hydrogen Natural Gas Still Gas (in refineries) Crude Oil … Ester (biodiesel, BD) Fischer-Tropsch Diesel (FTD) Liquid Hydrogen Methyl Tertiary Butyl Ether (MTBE) Ethyl Tertiary …
Last Updated Thu, 06/19/2025 - 15:31
FAQ
… the house-line regulator needs this pressure to supply hydrogen to the application and control accurately.  The PB …
Last Updated Fri, 04/18/2025 - 19:10
FAQ
… to be used, although the ISO standard does not yet include hydrogen in its scope and is for CNG tanks only. Commercial …
Last Updated Thu, 06/19/2025 - 15:14
FAQ
… for maintenance to ensure that a flammable mixture of hydrogen can’t be formed when the system is exposed to air. …
Last Updated Thu, 10/10/2024 - 14:01
Fuel Cell Codes and Standards
… propane, and butane); c) alcohols, (methanol, ethanol); d) hydrogen The following points also apply: · The heat transfer …
Last Updated Thu, 12/12/2024 - 18:44
Fuel Cell Codes and Standards
… Methanol, Ethanol; d. Gasoline; e. Diesel; f. Kerosene; g. Hydrogen; h. Chemical Hydrides; and i. Metallic. 1.1.4 The …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… A hydrogen gas holder exploded.It is assumed that there was diaphragm leak in the hydrogen-oxygen electrolytic cell used to produce high purity hydrogen for a pharmaceutical hydrogenation. … Explosion in a …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… A pressure relief device (frangible burst disk) on one of a hydrogen delivery tube trailer`s 26 tubes failed prematurely and released hydrogen while filling a hydrogen storage tank at a government facility. … …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… A cylinder filled with hydrogen exploded. Hydrogen is used to blow up balloons … Explosion of Cylinders …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… when executing a test studying the performance of a hydrogen gas flow measuring system for fuel feeding system of the rocket. During testing of a 42 MPa high-pressure hydrogen gas flow system, an exhaust gas duct outlet was damaged; hydrogen blew out and exploded. Apparently the cause of this …
Last Updated Fri, 10/25/2024 - 20:24
Fuel Cell Codes and Standards
… in the conversion of input fuel and oxidizer into a hydrogen-rich product gas stream suitable for use in fuel …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… An aerosol of hydrogen, hydrogen chloride and sulfuric acid is released in a plant … due to the deterioration of the anticorrosion coating. Hydrogen permeated through the diaphragm and mixed with …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… Explosion of nitrobenzene fluoride while mixing with hydrogen gas: Fluoronitrobenzene exploded when mixing it with compressed hydrogen gas. … Explosion During a Chemical Reaction (642) …