A catastrophic failure of the low pressure turbine followed by fire and flooding severely damaged the generator. The main turbine automatically tripped due to an erroneous mechanical over speed…
The event occurred during the disconnection of the hydrogen compressor for maintenance.Two deaths and three injured workers were the consequences. The cause(s) of the event are unknown.
Leak from faulty hydrogen seal ignited by short circuit between inboard slip ring and outboard slip ring radial lead connection. Hydrogen flame caused damage to brush gear assembly and inboard slip…
Hydrogen gas leaking from drain pipes in a hydrodesulfurization plant: There was a hydrodesulfurisation plant which had a recycle hydrogen compressor fitted with a suction rectifier. Hydrogen gas…
Fire in chemical plant (Seveso-classified)The fire developed at the top of the flare stack of a during a violent thunderstorm.The flare stack is used to discharge hydrogen produced by the…
During repairs of a heat exchanger in a benzene plant, a mixed gas (methane and hydrogen) contained in the cold box attached to the exchanger leaked and caught fire from a welding spark. The…
A ruptured hydrogen line caught fire at a commercial gas plant.
A fire in a leaking hydrogen unit at a 220,000-barrel oil sands plant temporarily cut production nearly 80 percent.
A fire in a metallurgical plant (classified Seveso)The fire initiated in a acid treatment reactor of a workshop handling cementation of indium . Under normal conditions, the reaction of the process…
Fire due to hydrogen gas leakage from a cadre falling in transportation.
Leaking hydrogen ignited a fire that burned several hours at an oil refinery.
An operator had just replaced the ignition port cover on a hydrochloric acid plant burner. Normal start-up was continued by closing the drain valve in the product run off line and opening the…
Unit tripped on-load due to serious fire between alternator and number 12 bearing. Fire extinguished by fire brigade. No injuries. Serious site damage was sustained to in CT chamber and alternator…
The Unit for Catalysed Removal of Carbon Dioxide (Catacarb) leaked and hydrogen fire at the hydrocracking unit. The fire lasted approximately 10 minutes. Localized corrosion caused a pipe to fail and…
Two successive fires broke out in an interval of few minutes in four cells in the electrolysis room of a chlorine production plant. The technicians brought the fire under control using the fire-…
The fire started in a electrolysis cell. The fire originated from a hydrogen leak in the hydrogen over pressure control system of the cell and an unidentified ignition source. The ARIA report (sew…
At a refinery, a leakage and fire occurred during usual operation at a medium-pressure hydrocracker for the desulfurization and decomposition of heavy gas oil. Gas of high-temperature and high-…
A fire occurred in a hydrogen and catalyst loading lines of heavy oil unit. The most likely cause was that a hydrogen purge pipeline failure allowing hydrogen to escape. This mixed with hot oil…
A fire occurred at a refinery hydrocracker plant involving a gauge glass and hydrogen gas oil.
When waste alkali solution was taken out of dumper trucks into a waste liquid storage tank, a reaction occurred in the tank. As a result, the solution in the tank foamed over it, and reached an…