An in-line inspection of the hydrogen pipeline was being conducted and prior to the last run of the in-line inspection tool (mfl), hydrogen gas was released and ignited from a blind flange connection…
Employees #1 - #3 were machinists that were in the process of trouble shooting a compressor which had hydrogen in the lines. No actual work was in process. They were only listening for obvious noises…
An explosion occurred in a water skim tank associated with an ethyl benzene dehydrogenation reactor system. The reaction mixture from the reactors containing styrene, ethylbenzene, benzene, toluene…
A fire occurred in a pipe trench containing about 50 pipelines.The pipelines were carrying a wide variety of hydrocarbons from crude oil to residuals. In addition, there were lines with steam, fuel…
During agricultural drainage work carried out by a farmer, an explosion occurred on a hydrogen pipeline located in a field. Flames several meters high were visible and two houses were evacuated. A…
A ruptured hydrogen line caught fire at a commercial gas plant.
Fire broke out along a transition corridor combining several underground pipelines transporting hazardous substances, including hydrogen, kerosene and ethylene oxide. The fire was brought under…
Excavation work was performed nearby a buried pipeline of gaseous hydrogen. The excavation machine hit the pipeline causing an under-expanded jet fire. No injuries. The excavation machine was burnt…
Two mechanic workers had picked up a work permit for the removal of filters from a hydrogen line. An operator also visited the scene and answered the mechanics question as to whether the line should…
A fire was sparked by a hydrogen leak at a Goodrich plant around 9:50 a.m. Friday, safety officials said. "Apparently the hydrogen caused a fire when it hit the air," said Chief Alex Rodriguez of the…
Early in the morning of (3:00 AM), the personnel on one of the companies on site reported a potential pipeline leak just south of the valve station. The potential leak was discovered due to bubbling…
A hydrogen release and subsequent fire occurred at meter station of a pipeline transporting hydrogen to a refinery. Local refinery emergency response team responded and secured the area. The pipeline…
Alarm received by firefighters around midnight by a resident who heard abnormal noise under the Beaumont Bridge while walking his dog.Perimeter of security set up very quickly with isolation of the…
The incident involves a gas booster provided by a manufacturer. This device is used in the experimental platform of the project to raise the pressure in pipelines from 60 to 80 barg (from 6 to 8 MPa…
During maintenance work on a gas pipeline carrying hydrogen , a worker hears a leak at about at a bridge. The operator measures an concentration of 3% of the low flammability limit at few…
A leak of a flammable mixture of hydrocarbons and hydrogen from a ruptured pipeline caused an explosion and fire, killing one person and injuring forty six. Investigations into the incident found…
At 17:30 on 5 may 2019, the pipeline operator was notified by a third party that there was a possible leak on its hydrogen pipeline, as identified by sound. Operator personnel arrived on the site at…
Release from a welding of a hydrogen transmission pipeline At 12:45 pm the operation control centre (OCC) recognised that a customer flow and pressure dropped significantly. At 13:28 the OCC made the…