Skip to main content

Water evaporation over sump surface in nuclear containment studies: CFD and LP codes validation on TOSQAN tests

Type of Publication
Year of Publication
2013
Authors

J. Malet; Ddu Lou; T. Gelain

Abstract

During the course of a severe accident in a Nuclear Power Plant, water can be collected in the sump containment through steam condensation on walls and spray systems activation. The objective of this paper is to present code validation on evaporative sump tests performed on TOSQAN facility. The ASTEC-CPA code is used as a lumped-parameter code and specific user-defined-functions are developed for the TONUS-CFD code. The seven tests are air-steam tests, as well as tests with other non-condensable gases (He, CO2 and SF6) under steady and transient conditions (two depressurization tests). The results show a good agreement between codes and experiments, indicating a good behavior of the sump models in both codes. The sump model developed as User-Defined Functions (UDF) for TONUS is considered as well validated and is 'ready-to-use' for all CFD codes in which such UDF can be added. The remaining discrepancies between codes and experiments are caused by turbulent transport and gas mixing, especially in the presence of non-condensable gases other than air, so that code validation on this important topic for hydrogen safety analysis is still recommended. (c) 2013 Elsevier B.V. All rights reserved.

DOI

10.1016/j.nucengdes.2013.05.009

Volume

263

Notes

Times Cited: 2 Ollendorff, Christine/D-1264-2010 2

Pagination

395-405

ISSN Number

0029-5493

We are professional and reliable provider since we offer customers the most powerful and beautiful themes. Besides, we always catch the latest technology and adapt to follow world’s new trends to deliver the best themes to the market.

Contact info

We are the leaders in the building industries and factories. We're word wide. We never give up on the challenges.

Recent Posts