Skip to main content

HySafe SBEP-V20: Numerical studies of release experiments inside a naturally ventilated residential garage

Type of Publication
Year of Publication
2010
Authors

E.A. Papanikolaou; A.G. Venetsanos; M. Heitsch; D. Baraldi; A. Huser; J. Pujol; J. Garcia; N. Markatos

Abstract

This work presents the results of the Standard Benchmark Exercise Problem (SBEP) V20 of Work Package 6 (WP6) of HySafe Network of Excellence (NoE), co-funded by the European Commission, in the frame of evaluating the quality and suitability of codes, models and user practices by comparative assessments of code results. The benchmark problem SBEP-V20 covers release scenarios that were experimentally investigated in the past using helium as a substitute to hydrogen. The aim of the experimental investigations was to determine the ventilation requirements for parking hydrogen fuelled vehicles in residential garages. Helium was released under the vehicle for 2 h with 7.200 l/h flow rate. The leak rate corresponded to a 20%2drop of the peak power of a 50 kW fuel cell vehicle. Three double vent garage door geometries are considered in this numerical investigation. In each case the vents are located at the top and bottom of the garage door. The vents vary only in height. In the first case, the height of the vents is 0.063 m, in the second 0.241 m and in the third 0.495 m. Four HySafe partners participated in this benchmark. The following CFD packages with the respective models were applied to simulate the experiments: ADREA-HF using k-epsilon model by partner NCSRD, FLACS using k-epsilon model by partner DNV, FLUENT using k-epsilon model by partner UPM and CFX using laminar and the low-Re number SST model by partner JAC. This study compares the results predicted by the partners to the experimental measurements at four sensor locations inside the garage with an attempt to assess and validate the performance of the different numerical approaches. (C) 2010 Professor T. Nejat Veziroglu. Published by Elsevier Ltd. All rights reserved.

DOI

10.1016/j.ijhydene.2010.02.020

Volume

35

Notes

Times Cited: 13 Garcia, Javier/J-6820-2012 Garcia, Javier/0000-0002-2986-7228 Si 13

Pagination

4747-4757

Number
10
ISSN Number

0360-3199

We are professional and reliable provider since we offer customers the most powerful and beautiful themes. Besides, we always catch the latest technology and adapt to follow world’s new trends to deliver the best themes to the market.

Contact info

We are the leaders in the building industries and factories. We're word wide. We never give up on the challenges.

Recent Posts