A facility is described that allows safe handling of high tritium gas activity as dozens kilocuries in a regular laboratory environment. It is used to make and deliver into the target a mixture of specific isotopic composition with the contamination requirement of 10(-7) v.f. for Z>1 elements, and recover it upon completion of operation. With this facility, efforts have been accomplished to investigate into the muon catalyzed fusion on two targets - liquid tritium and high-pressure tritium types. Also, the operation range was 0.1-120 MPa for pressure and 20-800 K for temperature and the amount of tritium used was about 100 kCi. The facility showed reliability in operation without indications of radiation beyond the safety level.
10.1023/a:1012684819789
119
Times Cited: 12 International Workshop on Exotic Atoms, Molecules and Muon Catalyzed Fusion (EXAT98) Jul 19-24, 1998 Univ fribourg, fribourg, switzerland ETH Zurich, Ctr Stefano Franscini; Paul Scherrer Inst; Univ Fribourg; Swiss Natl Fdn 12
341-344
0304-3843