Abstract

The behaviour of hydrogen mixing and distribution has always been an important safety issue and the hydrogen distribution studies gained importance especially after Fukushima accident. The hydrogen generated due to metal water reaction releases into the containment and may get stratified locally under accident conditions. The stratification of hydrogen may be eroded by diffusion or by other means. CFD codes are increasingly being used for hydrogen distribution analysis and need to be validated before applying it to full scale containment simulations. In this context, the CFD code FLUENT is validated against the experiment conducted in the MISTRA facility on stratification and erosion behaviour. This paper deals with the validation of the CFD code FLUENT against the experiment conducted in MISTRA facility to study the stratification behaviour. Turbulence model sensitivity was carried out to identify the best suited turbulence model. (C) 2014 Elsevier Ltd. All rights reserved.

DOI

10.1016/j.anucene.2014.01.034

Volume

69

Notes

Times Cited: 0 0

Pagination

37-43

ISSN Number

0306-4549