A major requirement for the filling of hydrogen tanks is the maximum gas temperature within the vessels during the process. Different filling strategies in terms of pressure and temperature of the gas injected into the cylinder and their effects on key parameters like maximum temperature, state of charge, and energy cooling demand are investigated. It is shown that pre-cooling of the gas is required but is not necessary for the whole duration of the filling. Relevant energy savings can be achieved with pre-cooling over a fraction of the time. The most convenient filling strategy from the cooling energy point of view is identified: with an almost linear pressure rise and pre-cooling in the second half of the process, a 60%2reduction of the cooling energy demand is achieved compared to the case of pre-cooling for the whole filling. Copyright (C) 2014, The Authors. Published by Elsevier Ltd on behalf of Hydrogen Energy Publications, LLC.
10.1016/j.ijhydene.2014.10.138
40
Times Cited: 2 2
735-745
0360-3199