Type of Publication
Year of Publication
2002
Authors

Z.S. Xu; F.Y. Wang

ISBN Number

7-03-010787-X

Abstract

In order to find out the real explosion reasons of the 300 m(3) wet-gas hydrogen holder in a power company, Disaster Prevention Science and Safety Technology Institute (DPSSTI) carried out the investigation on the explosion accident scene. Based on the calculation and analysis of the explosion accident causes, the explosion accident's reasons are discussed, and the safe-defense measures to prevent the occurrence of similar accidents are put forward.

Volume

3

Notes

Times Cited: 0 3rd International Symposium on Safety Science and Technology (2002 ISSST) Oct 10-13, 2002 Tai an, peoples r china Chinese Soc Sci & Technol Labor Protect; Beijing Inst Technol; Shandong Univ Sci & Technol; Journal Safety & Environm, Editorial Dept 0

Pagination

1256-1263