… silicone coatings. The blast occurred when some polymethyl hydrogen siloxane was accidentally fed into a reactor, together with the … glycidyl ether. The two epoxides reacted, overheated and hydrogen burst out of a ruptured pipe into the building, …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… The methanation reactor vessel was found to be deformed and had a 3-4 inch rupture at a … top of the catalyst bed. It is though that the incident was caused by ethylene entering the reactor. The ethylene reacted with hydrogen on the nickel catalyst, resulting in a very rapid …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… The failure of a high pressure hydrogen-based synthetic gas feed line to the ammonia … explosion followed by a severe fire. One of the operators was fatally injured. The failure of the feed line was characterized by a sudden rupture. There was no leakage …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… The FCEV was travelling at approx. 75 km/h (80 km/h speed limit) on a straight, downhill part of the road. Another vehicles was waiting at a STOP sign on the right side, did not see the … back right side. There were only body parts damaged and no hydrogen was released. There was no oil or other fluid …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… In a chemical plant, a fire broke out on a hydrogen column of an ammonia manufacturing unit. The … the fire with powder and nitrogen injection. The unit was cooled with water. … Fire on an Ammonia Production Unit …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… in a ammonia plant.The accident starts with a leak of a hydrogen-nitrogen mixture at the suction flange of a …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… different units of a refinery: It consists first in a non-hydrogen accident, followed by a hydrogen-related … the electrical cables running near the vessel. This fire was completely extinguished before the second accident. … the explosion point. The fire following this explosion was of short duration.The incident occurred in a zone in …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… occurred in a gaseous waste decay tank while the plant was in cold shutdown. The gaseous hydrogen present in the tank formed a flammable mixture and … concentration to less than 3 percent.The source of air was identified as instrument air leaking through check valves …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… The gas leak containing hydrogen (H2) and hydrogen sulfide (H2S) occurred at the … into the low-pressure section. A maintenance intervention was scheduled to replace one of the faulty level sensor. … a leak. Thirty minutes later, the upper part of the valve was ejected under the effect of pressure, causing the release …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… The explosion involving hydrogen gas knocked a 36-by-70-foot hole in the roof of the plant. Officials said the gas was formed when chemicals mixed in the plant's waste …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… electrolysis plant. The explosion is due to the entry of hydrogen in the oxygen gas holder.The dome of the gas holder …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… waste water tank Hydrogen that causes the incident has been produced either …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… unit used to desulfurise raw diesel be means of hydrogen.The facility was expected to begin full commercial operations later in …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… sized balloons of the same company). The inner balloon was a meteorological balloon made of latex. When starting filling the inner balloon with hydrogen (final full balloon relative pressure of 0.03 bar) a leak was noticed, due to a small rupture in the skin of the latex …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… of Isopropanol as solvent and Raney nickel as catalyst. Hydrogen and the other reacting components is injected into a … to 40%-50% of his body and died 15 days later. The plant was destroyed. Glass panes shattered over a 50-100 m radius; the distillation unit adjoining the bunker was also damaged, causing the isopropanol and TDA to leak …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… during welding works which ignited accidentally released hydrogen. The plant had been partially shut down for … drying of the pipe section, further water leakage was hindering the work, so that additional measures was taken, also to avoid too much gas waste. The hydrogen
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… batch manufacturing of a soft reducing agent, an operator was rinsing the 3000-litre reactor first with a solvent and … sodium hydride (NaH) residues on the reactor walls to form hydrogen. The hydrogen then mixed with air outside the reactor to form a …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… There was a small leak of syngas (a mixture mainly consisting of hydrogen and carbon monoxide) resulting in a localized fire …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… A leak of a flammable mixture of hydrocarbons and hydrogen from a ruptured pipeline caused an explosion and …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
Hydrogen was accidentally produced inside the sealed …