In the acid treatment room of a Seveso low-threshold hazardous waste treatment centre, an explosion occurred on a 250 m concrete tank containing acid sludge being neutralized. The explosion occurred…
The explosion occurred in an incinerator for non-industrial wastes, during inspection and repair works. These were due to a large quantity of aluminum which produced a solid lump of ash. The…
Works at the power grid of a hydrogen production unit is at the origin of the sequence of the following events:1.Fusion of a safe fuse triggering the closure of a valve on the manifold of a pistons…
Five barrels of aluminum dust that had been removed from an outdoor dust collector were sealed and stored in the plant adjacent to electrical panels. One of them had somehow been contaminated with…
The vent occurred at the hydrogen manufacturing unit: a pipe of this unit burst, followed by an explosion. The fire was extinguished in about 15 minutes. One employee nearby had a consequence from a…
In this plant, after conversion of the major part of the carbon dioxide into urea, the off-gasses from the reactor consist of ammonia, carbon dioxide, hydrogen, oxygen and nitrogen. Prior to venting…
An explosion without fire or gas emission occurred in the washer of the catalyst activation unit. The unit was stopped for maintenance : 3 external employees were checking the washer. The explosion…
Explosion at chemical plant in Akita Prefecture involving hydrogen killed a worker
An explosion occurred in the Heat Treatment Shop of this site. The explosion was centered in the electrical control panel of the High Velocity Oxy Fuel (HVOF) thermal spraying equipment. The violent…
In a chlorine manufacturing unit, an explosion occurs in the room of the electrolysis cells. The accident occurs during the start-up phase of the unit, it is due to the presence of hydrogen in the…
An explosion occurred in an electrostatic precipitator whilst it was being accessed for maintenance. The explosion caused an inspection hatch cover, which had been unbolted, to be blown off and…
During functional tests of the system, a major quantity of hydrogen-containing gas was released from an adsorber, followed by its ignition.After the alarm was released the feed of the adsorber was…
On a cold morning, the gasoil hydro-treatement unit was being brought back on line after being out of service to repair a governor problem on the recycle gas compressor. Several upset trips had…
The Microbiological Anaerobic Chamber of approximately 2 m3 capacity was containing an explosive mixture of hydrogen and air. A fire followed the explosion, but was rapidly extinguished by staff…
An explosion occurred in the glass components of a reactor at a pharmaceutical plant during a batch process. At the time of the accident, the reactor was being hydrogenated. As a result of the…
"A chlorine suction pump failed on a sodium hydroxide electrolysis unit.Recovery operations were carried out including nitrogen purging of hydrogen piping and air purging of chlorine piping before…
In a graphite purification workshop, the cooling circuit of an electric furnace leaks, the water decomposes in contact with materials heated to a temperature of 1,800C; the gas mixture (hydrogen,…
Explosion in a chemical manufacturing plant for the pharmaceutical and cosmetics industries, classified as Seveso high level, The explosion occurred in the hydrogenation reactor, when opening two…
Explosion in a food products plant (Seveso classified)The event occurred in the settling cyclone of a hydrogenation reactor of a starch production unit. The process consists in introducing the starch…
The accident occurred during the night during the production of a silicon oil- and additive-based waterproofing agent. A junior technician (hired 6 months back), recently assigned to this post, was…
In a chemical plant, an explosion occurred on the primary reformer of an ammonia manufacturing unit.
A major leak (estimated between 1.5 and 3 kg) of hydrogen from high-pressure storage, resulted in a detonation, from hydrogen a refuelling station.Causes were two untightened bolts securing the…
A hydrogen leak occurred on the a coolant pipe of an electrical generator located in the turbine building, at 200 m from the reactor. Because of the welding works ongoing at that moment on the pipe…
The incident occurred at the hydrogen coolant circuit, when purging the hydrogen with carbon dioxide and air, aiming at finding a leak. Following a preliminary investigation, the power plant company…
An in-tank explosion occurred in a gaseous waste decay tank while the plant was in cold shutdown. The gaseous hydrogen present in the tank formed a flammable mixture and ignited due to air…
A cylinder filled with hydrogen exploded. Hydrogen is used to blow up balloons
In a chemical plant, a 1750 m tank containing an ammoniac solution explodes. The anchorage of the was ripped, the tank lifted on one side and crashed against the retention wall, which was partially…
The pressure vessel in a chlorine separation system exploded after the corrosion of the steel process equipment allowed chlorine and hydrogen to mix and form a volatile mixture. The chlorine…
Huge explosion of liquid chlorine mixed with hydrogen took place on pulp and paper plant in Arkhangelsk. More than 50 tons of liquid chlorine exploded.
The incident occurred in a catalytic reforming unit. At 13:41, a leak occurred at the 90 elbow of a pressure pipe containing a mixture of hydrogen and naphtha. This pipe was located between the pre-…