Abstract
Numerical experiments are performed to understand different regimes of hydrogen non-premixed combustion in an enclosure with passive ventilation through one horizontal or vertical vent located at the top of a wall. The Reynolds averaged Navier–Stokes (RANS) computational fluid dynamics (CFD) model with a reduced chemical reaction mechanism is described in detail. The model is based on the renormalization group (RNG) k-
Year of Conference
2013
Volume
39
Number of Pages
10788-10801
ISBN Number
0360-3199
DOI
10.1016/j.ijhydene.2014.05.007