In this study, the strength safety for 110 liter hydrogen fuel storage tank with 70MPa filling pressure has been analyzed using a FEM technique. The strength safety of a composite fuel tank in which is fabricated by an aluminum liner of 6061-T6 and carbon fiber wound composite layers of T800-24K and T700-12K of Toray, and MR60H-24P of Mitsubishi Ray has been investigated based on the criterion of a strength safety of US DOT-CFFC and Korean Standard. The FEM computed results on the strength safety of 70MPa hydrogen gas tank showed that the hydrogen fuel storage tank in which is fabricated by T800-24K and T700-12K of Toray, and MR60H-24P of Mitsubishi Ray is safe because those two carbon fibers have very similar material properties. But, the composite storage tank with a filling pressure of 70MPa in which is fabricated by T700-12K of Toray may not guaranty the strength safety, and thus this study recommends a composite hydrogen fuel tank under 60MPa. 70MPa 110L FEM . 6061-T6 Toray T800-24K T700-12K, Mitsubishi Ray MR60H-24P DOT-CFFC KS . 70MPa FEM , Toray T800-24K Mitsubishi Ray MR60H-24P 70MPa . , Toray T700-12K 70MPa 60MPa .

Year of Publication
2012
Volume
16
Number of Pages
16-21
ISBN Number
1226-8402