This paper presents a strength safety evaluation of composite pressure container for hydrogen fuel tanks with a storage capacity of 104 liter and 70MPa pressure. The carbon fiber composite container is manufactured by an aluminum liner of Al6061-T6 and composite multi-layers of hoop winding layer in circumferential direction, 12 inclined winding layer and 70 winding layer in helical direction respectively. The FEM results on the strength safety of composite fuel tanks were evaluated with a criterion of design safety of US DOT-CFFC and KS B ISO 11119-2 codes. The FEM computed results indicate that the proposed design model of 104 liter composite container is safe based on two strength safety codes. But, the computed results of carbon fiber fuel tanks based on US DOT-CFFC code is safer compared with that of KS B ISO 11119-2. Thus the hydrogen gas pressure container of 70MPa may be evaluated and designed by US DOT-CFFC code for more strength safety. 104L 70MPa . 6061-T6 , , 12 70 . FEM US DOT-CFFC KS B ISO 11119-2 . FEM , 104L US DOT-CFFC KS B ISO 11119-2 . , . 70MPa DOT-CFFC .

Year of Publication
2011
Volume
15
Number of Pages
30-34
ISBN Number
1226-8402