Skip to main content
Abstract

A gas recycling system to prevent losses of isotopically enriched hydrogen gas has been developed for the operation of a liquid target (2.7 1) used by the Radiative Muon Capture group at TRIUMF. The experimental requirements for high gas purity (chemical impurities below 10(-9)), low operating pressure (below 1 bar abs) and high loading pressure (about 10 bar needed for a palladium purifier) together with the usual hydrogen safety requirements were satisfied with a metal hydride storage device in combination with a small pump/compressor system. A description of the complete system together with its characteristic operational data are given in this paper.

Year of Publication
1995
Journal
Nuclear Instruments & Methods in Physics Research Section a-Accelerators Spectrometers Detectors and Associated Equipment
Volume
355
Number of Pages
230-235
ISBN Number
0168-9002
Accession Number
WOS:A1995QJ70600005
DOI
10.1016/0168-9002(94)01085-4
Alternate Journal
Nucl Instrum Meth A