Skip to main content
Abstract

The behaviour of hydrogen mixing and distribution has always been an important safety issue and the hydrogen distribution studies gained importance especially after Fukushima accident. The hydrogen generated due to metal water reaction releases into the containment and may get stratified locally under accident conditions. The stratification of hydrogen may be eroded by diffusion or by other means. CFD codes are increasingly being used for hydrogen distribution analysis and need to be validated before applying it to full scale containment simulations. In this context, the CFD code FLUENT is validated against the experiment conducted in the MISTRA facility on stratification and erosion behaviour. This paper deals with the validation of the CFD code FLUENT against the experiment conducted in MISTRA facility to study the stratification behaviour. Turbulence model sensitivity was carried out to identify the best suited turbulence model. (C) 2014 Elsevier Ltd. All rights reserved.

Year of Publication
2014
Journal
Annals of Nuclear Energy
Volume
69
Number of Pages
37-43
ISBN Number
0306-4549
Accession Number
WOS:000335107500005
DOI
10.1016/j.anucene.2014.01.034
Alternate Journal
Ann Nucl Energy
We are professional and reliable provider since we offer customers the most powerful and beautiful themes. Besides, we always catch the latest technology and adapt to follow world’s new trends to deliver the best themes to the market.

Contact info

We are the leaders in the building industries and factories. We're word wide. We never give up on the challenges.

Recent Posts