Skip to main content
Abstract

High gas temperatures can be reached inside a hydrogen tank during the filling process because of the large pressure increase (up to 70-80 MPa) and because of the short time (similar to 3 min) of the process. High temperatures can potentially jeopardize the structural integrity of the storage system and one of the strategies to reduce the temperature increase is to pre-cool the hydrogen before injecting it into the tank. Computational Fluid Dynamics (CFD) tools have the capabilities of capturing the flow field and the temperature rise in the tank. The results of CFD simulations of fast filling with pre-cooling are shown and compared with experimental data to assess the accuracy of the CFD model. Copyright (C) 2014, Hydrogen Energy Publications, LLC. Published by Elsevier Ltd. All rights reserved.

Year of Publication
2014
Journal
International Journal of Hydrogen Energy
Volume
39
Number of Pages
4389-4395
ISBN Number
0360-3199
Accession Number
WOS:000333881500027
DOI
10.1016/j.ijhydene.2013.12.196
Alternate Journal
Int J Hydrogen Energ