Abstract
It is demonstrated that metal properties depend strongly on both hydrogen concentration, and on its redistribution with respect to bonding energy. According to accident statistics presence of hydrogen within metal is in many cases the main reason for metal structure breakdown with occurrence of internal stresses. It is concluded that the lack of a single metrological hydrogen concentration measurement system makes it impossible to introduce extensively an effective and reliable method for production monitoring and accident prevention.
Year of Publication
2013
Journal
Measurement Techniques
Volume
56
Number of Pages
328-333
ISBN Number
0543-1972
Accession Number
WOS:000321786000023
DOI
10.1007/s11018-013-0204-3
Alternate Journal
Meas Tech+