Skip to main content
Abstract

An experimental investigation is conducted into the nature of catalytic ignition of leaked hydrogen gas within an enclosure, and the nature of hydrogen dispersion under varied venting conditions. Using a 1/16th linear scale two-car garage as a model, and a platinum foil as a catalytic surface, it is found that for all conditions tested, catalytic ignition is observed after the leaked hydrogen comes in contact with the catalytic surface, which is initially at or near room temperature. After ignition, these surface reactions lead to steady-state surface temperatures in the range of 600-800 K, dependent on inlet conditions in terms of mixture composition and flow rate. In addition, varying the venting opportunities from the garage walls suggests that not only total area, but also the number and position of vents may impact the nature of hydrogen accumulation within an enclosed structure. Copyright (c) 2012, Hydrogen Energy Publications, LLC. Published by Elsevier Ltd. All rights reserved.

Year of Publication
2012
Journal
International Journal of Hydrogen Energy
Volume
37
Number of Pages
10405-10415
ISBN Number
0360-3199
Accession Number
WOS:000306038800057
DOI
10.1016/j.ijhydene.2012.03.146
Alternate Journal
Int J Hydrogen Energ