In order to analyze the effects of the spray activation on the behavior of steam and hydrogen which are produced in the reactor vessel and released into the containment of the APR1400 nuclear power plant during hypothetical severe loss-of-coolant accidents (LOCA), the 3-dimensional CFD code GASFLOW was used. For the two-phase flow with a gas mixture and spray droplets, GASFLOW solves a homogeneous two-phase model which was validated in this study by simulating one of the TOSQAN experiments. The results of the GASFLOW analyses for the LOCAs in the APR1400 show that the spray system can affect the hydrogen distributions in the containment by condensing the steam and it is important to control the spray system carefully during an accident from a hydrogen safety aspect. (c) 2006 Elsevier Ltd. All rights reserved.

Year of Publication
2006
Journal
International Communications in Heat and Mass Transfer
Volume
33
Number of Pages
1207-1216
ISBN Number
0735-1933
Accession Number
WOS:000242707800004
DOI
10.1016/j.icheatmasstransfer.2006.08.014
Alternate Journal
Int Commun Heat Mass