Abstract

A facility is described that allows safe handling of high tritium gas activity as dozens kilocuries in a regular laboratory environment. It is used to make and deliver into the target a mixture of specific isotopic composition with the contamination requirement of 10(-7) v.f. for Z>1 elements, and recover it upon completion of operation. With this facility, efforts have been accomplished to investigate into the muon catalyzed fusion on two targets - liquid tritium and high-pressure tritium types. Also, the operation range was 0.1-120 MPa for pressure and 20-800 K for temperature and the amount of tritium used was about 100 kCi. The facility showed reliability in operation without indications of radiation beyond the safety level.

Year of Publication
1999
Journal
Hyperfine Interactions
Volume
119
Number of Pages
341-344
ISBN Number
0304-3843
Accession Number
WOS:000080977500048
DOI
10.1023/A:1012684819789
Alternate Journal
Hyperfine Interact