Skip to main content

Hydrogen trains require safety considerations for high g-loads and tunnel operations, but no major barriers exist for properly designed systems.

Are there any specific considerations, hazards or safety barriers that are applicable to the operation of hydrogen trains?

Hydrogen has been used as a fuel to operate cars, buses, trucks, submarines, aircraft, forklifts, trains and virtually every type of mobile equipment. Each has special considerations which often drive specific requirements for that vehicle type. For example, higher g-loadings of rail operations and operations within tunnels are a couple considerations, but there are no significant barriers that would prevent the application of hydrogen for trains for a properly designed system.

FAQ Category
FAQ Keyword
Submission Year
2023
Month
04

The sub-cooled hydrogen fueling method involves unique safety considerations related to operating at low pressures and handling cryogenic liquids similar to industrial gas systems.

What are the unique safety considerations with the sub-cooled hydrogen fueling method that Daimler Truck has developed?

All systems must be designed for the applicable operating parameters such as pressure, temperature,
and flow. The sub-cooled liquid hydrogen (sLH2) approach for fueling is comparable to other processes
commonly used to handle cryogenic liquids in the industrial gas industry where remaining gas is
condensed during the fill operation. These processes often operate above the critical pressure and/or
temperature of the fluid. A sLH2 system operates at much lower pressure, under 20 bar (290 psi), than
“cryo-compressed” hydrogen (CCH) systems which commonly operate at 350 bar(5100 psi). sLH2 systems
operate more like a liquid hydrogen (LH2) system that operates at a slightly higher pressure, while a CCH
system is more comparable in operation to a high pressure gas system.

FAQ Category
Submission Year
2023
Month
04

Hydrogen leak detection systems are typically included in heavy-duty fuel cell trucks, with design specifics determined by manufacturers as standards evolve.

Do heavy-duty hydrogen fuel cell trucks have a requirement to detect hydrogen leaks with sensors near their fuel cell system and/or near their hydrogen storage tanks?

Detection systems are nearly always installed but the system design and installation details of detection equipment are up to the manufacturer. Standards are being developed for this market.

FAQ Category
Submission Year
2023
Month
04

Technicians PPE for Maintaining FCVs

Are there any detailed guidelines or requirements regarding the specific types of personal protective equipment (PPE) that should be worn by technicians maintaining fuel cell vehicles (FCVs)?

The Hydrogen Safety Panel is not aware of any detailed guidelines or requirements. There are general requirements for personal protective equipment (PPE) in relevant codes and standards, but these often defer to the manufacturers requirements or a material safety data sheet (MSDS) for specifics. Ultimately, PPE selection is a matter between the employer and the employee and may need to consider state and federal regulations, company policies and the employees work assignment. The information below is provided for consideration when working fuel cell systems equipped with hydrogen storage tanks and related hydrogen piping systems.

In general, the pressurized gaseous hydrogen system should be defueled and the high-voltage electrical system de-energized[1]  (in accordance with standard operating procedures) before any maintenance is performed. If this is done, then the PPE will likely need to be similar to repair garage activities for other (non-hydrogen) vehicles, and may include:

  • Safety shoes
  • Safety glasses
  • Hand protection (to avoid cuts and abrasions)
  • Long sleeve shirts and full length pants (Note: Personnel should avoid wearing clothing made of nylon or other synthetics, silk, or wool because these materials produce charges of static electricity that can ignite flammable gas mixtures.)
  • Hard hats (when necessary)
  • Hearing protection (when necessary)

If the portion of the hydrogen system to be repaired can be isolated (preferably by at least two means) and defueled prior to any maintenance activity, then it may be possible to avoid defueling the entire pressurized hydrogen system on the vehicle. In this case, additional PPE may be required depending on the proximity to other systems that are still pressurized:

  • Flash fire resistive garments
  • Safety glasses with side shields, goggles or face shields
     

It is important to consider that the above guidance will not cover every activity or circumstance. Specific activities should be evaluated by safety professionals to determine the necessary engineering controls, work practices and PPE.

[1] Since all FCVs have high voltage systems additional PPE may be needed if working on an energized high voltage electrical portion of the vehicle.

FAQ Category
Submission Year
2023
Month
05

Fuel Cell Electric Vehicles (FCEVs) and Tunnel Safety

I am interested in alternate fuel vehicles such as fuel cell electric vehicles (FCEVs) and tunnel safety. Where can I find more resources on these topics?

Researchers from Sandia National Laboratories have conducted extensive research on these topics. They have reviewed the current literature, identified knowledge gaps in alternate fuel vehicles and tunnel safety, and developed a generalizable framework to assess tunnel safety for a diverse range of alternate fuel vehicles. Supported by US Department of Energy (DOE) and Federal Highway Administration (FHWA), their research focused on: 

  • Reviewing the current research on alternate vehicle type as they relate to hazards in tunnels and identifying knowledge gaps. Their findings are captured in this report 

  • Understanding the unique hazards associated different types of vehicles powered by gasoline, diesel, batteries, natural gas, propane, and hydrogen fuel cells

  • Developing a computationally inexpensive, adaptable, and generalized framework for assessing safety of alternate fuel vehicles in tunnels 

  • The framework incorporates accident scenarios, physics models and consequence models, tank blowdown calculations, parametric sensitivity analysis, studies of tank volume, orifice size, fullness, fuel type, and tunnel geometry characterization with a focus on high-traffic tunnel characteristics. 

Their research was presented at an FHWA webinar on November 9, 2023.  The presentation can be viewed here. The webinar recording is available here and the passcode is mPXM1wk&.

FAQ Category
FAQ Keyword
Submission Year
2023
Month
05

Hydrogen Detection Methods for Mobile Applications

What guidelines govern hydrogen detection methods for mobile applications using hydrogen as a fuel (not hazardous material transportation) in the USA or North America?

The UN ECE R134 regulation is a good requirement to follow as it copies the language in the UN GTR #13 regulation. The updated version of this UN document (UN GTR #13 Phase 2) is currently in approval review at the GRSP in Geneva and should be approved by the end of 2023. Nevertheless, since the US Department of Transportation’s National Highway Traffic Safety Administration is a contracting party to the UN GTR #13 development process, they have already begun a review of the Phase 2 document and are currently creating the FMVSS standard language for this new NHTSA requirement. It won’t become a Federal Motor Vehicle Safety Standards standard for at least 1.5 years, so for now it should be considered as a due diligence requirement for automotive FCEV applications. Since ECE R134 represents the latest embodiment of UN GTR #13, this is a long way to say that following R134 puts one in compliance with UN GTR #13 and hence would be following best practices in the USA (and Canada). 

From a vehicle design perspective, it is always best to ensure that locations where leaking hydrogen can accumulate are minimized/avoided, and that hydrogen sensors are placed in strategic locations where hydrogen can potentially collect. Potential ignition sources in areas where hydrogen can collect should also be avoided. If this safety concept is followed, then the 3% warning/4% shutdown strategy will work fine, although some original equipment manufacturers (OEMs) may choose to employ a stricter requirement of say, 2% warning/3% shutdown. In the event of a detected hydrogen leak, there is a requirement for the vehicle CHSS to be isolated but there is technically no requirement for the high voltage system to be isolated. Some OEMs may choose to leave HV on so that the vehicle may continue in limp mode to a safe location, while others might choose to isolate HV as well, leaving the operator with very limited remaining battery power to safely pull over. 


There are no requirements for the use of detectors for hazardous material transportation. Use of detection equipment is dependent upon the manufacturer and operator based on risk assessment.
 

FAQ Category
Submission Year
2023
Month
06

Tank Inspection Frequency

Is there a standard inspection timeline for Type 4 tanks in mobile applications in North America, or is this timeline set by the tank manufacturer? There references in some documents to an annual inspection being typical and that inspection needs to be conducted by a certified technician (CGA C-6.4 or similar).

It’s not clear if “mobile” in the question refers to vehicle fuel tanks, or vessels used for transportation of hazardous materials. 

  1. If it’s a Type 4 vessel for transportation of hazardous materials, it will be built to a special permit that details the inspection requirements. Special permits vary but they are generally consistent on a 5-year requalification period, which also includes a visual inspection by an inspector certified to CGA C-6.2 at that interval. 
  2. Since C-6.4 is mentioned, the question might pertain to vehicle fuel tanks. The C-6.4 document  recommends 36 months or less, but there are inconsistent requirements. The tank standard (ANSI/CSA HGV 2) originally required for a visual inspection every 36,000 miles or 3 years, whichever comes first, but the latest version states that the inspection is to be specified by the container manufacturer. There is an annex in HGV 2 that calls CGA C-6.4 or ISO 19078 to be used, although the ISO standard does not yet include hydrogen in its scope and is for CNG tanks only. Commercial vehicles such as trucks, buses and trailers also required an annual U.S. Department of Transportation (DOT) inspection to ensure that it complies with the Federal Motor Carrier Safety Regulations. This is a comprehensive check but does not have specific requirements for vehicle fuel tank inspection.
     
FAQ Category
Submission Year
2024
Month
04

Vehicle Transport Requirements

What are the considerations for the potential for hydrogen to leak from hydrogen fueled vehicles when they are being transported by truck, rail, or ship? What is the probability and quantity that might leak?

FCEVs usually contain only a minimal amount of hydrogen fuel pressure (several Mpa) to support getting the car on and off car carriers. Panel members are not aware of any hydrogen release incidents during vehicle loading and don’t know what the probability of such a leak is considering the loading operations. A risk assessment accounting for the probability of collisions as well as leaks from new cars off the assembly line would be needed. It may be best to connect with the car manufacturers when considering such an assessment. 

Regarding the questions on the source of leaks and leak rates, Section 5.2.2.2.2 of SAE J2579 (which is harmonized with the GTR) provides the following: The maximum allowable discharge (non-accident) from the compressed hydrogen storage system for passenger vehicles is A*150 Ncc/min where A = (Vwidth+1)*(Vheight+0.5)*(Vlength+1)/30.4 and Vwidth, Vheight, Vlength are the vehicle width, height, length (m), respectively. Simply speaking, the allowable leakage from the compressed hydrogen storage system of a passenger vehicle that fits in a standard garage in the USA is 150 Ncc/min. Note that the 150 Ncc/min limit for a typical passenger vehicle drops to an expected value of 7.5 Ncc/min (maximum) at a partial fill condition of 3 MPa. Potential sources for leaks during vehicle operation could include joints/fittings in the piping or at the fuel cell stack. This piping is typically at lower pressures than the storage vessel as a result of a system regulator.

Additionally, a solenoid valve is located in the tank. The solenoid closes when the key is turned off or the electrical system deenergized. The result is that only a very minimal amount of hydrogen would be in the piping system unless there is a failure of the solenoid. A useful diagram is included here, showing the hydrogen line connections in FCEV with Type 4 tank (source: Update to the 700 bar Compressed Hydrogen Storage System Cost Projection Webinar). This also shows a thermally activated pressure relief device integrated into the in-tank valve/regulator assembly as typical.

FAQ Category
Submission Year
2024
Month
04

Transportation Standards

Who can provide an understanding of the progress of U.S. hydrogen standards for H2 in transport? Is anyone working on standards for LH2 as a heavy vehicle fuel? ISO standards are available, but they are quite old now.

Generally speaking, the International Fire Code and NFPA 2 apply to non-transportation use of hydrogen. These are maturing quickly, with NFPA 2 currently having issued its most recent edition in 2023. Standards for both on-board LH2 tanks and LH2 tankers for bulk fuel transport are managed by the U.S. Department of Transportation (DOT) and are well established. DOT transport requirements for the U.S. can be found in 49 CFR. 


There is growing activity regarding the use of LH2 as a vehicle fuel and there are several prototype trucks in operation. The on-board tanks may lack some reference standards, but vehicle fuel storage systems are typically self-certified by the original equipment manufacturers, particularly at the current state of development. While there is risk of impeding the development of a commercial market due to a lack of approved and common hardware, there is also risk of finalizing a standard prior to completion of development and testing. ISO TC 197 has several working groups including WG 1 and WG 35 to further develop the necessary standards for fuel tanks, fueling connections, and filling protocols. Liquid hydrogen transfer is well proven and established for industrial applications. However, consumer use of a cryogenic product has not yet been proven and will require refinement of hardware and processes.


The vehicle manufacturers can also provide guidance as to their efforts to meet required regulations.
 

FAQ Category
Submission Year
2024
Month
04

Fueling

If bus fueling is done outdoors on a separate fueling island, and FCEB bus maintenance is done in a separate detached building modified to meet NFPA-1 and NFPA-2 with relevant gas detection, flame detection, electrical, alarms, etc., is it OK if the FCEB passes inside the main diesel maintenance building for 10-15 minutes to go through the bus wash and then immediately exit the facility? Is the bus's H2 system a completely contained system?

Hydrogen gas storage and fuel cell systems are typically closed systems with a variety of monitoring and control functions to prevent leaks. Please check with the bus manufacturer and authority having jurisdiction to verify this is acceptable per their direction. However, a good safety practice would be to minimize the time spent indoors for these activities. Hydrogen vehicles maintained in a facility should be provided with separation/isolation and appropriate safety control systems. Further guidance can also be provided by the local Authority Having Jurisdiction with regard to local regulations. 

FAQ Category
Submission Year
2024
Month
04
Subscribe to FC Electric Vehicles
We are professional and reliable provider since we offer customers the most powerful and beautiful themes. Besides, we always catch the latest technology and adapt to follow world’s new trends to deliver the best themes to the market.

Contact info

We are the leaders in the building industries and factories. We're word wide. We never give up on the challenges.

Recent Posts