Basic page
… relief is an essential element of both gaseous and liquid hydrogen storage systems to guard against excessive pressure … can result in a greater risk than the hazard for which it was installed. A significant consideration is that burst … contents. Some of the most serious incidents within the hydrogen industry have been associated with pressure-relief …
Last Updated Wed, 07/09/2025 - 15:39
FAQ
… The suspected cause was a mixture of oxygen and hydrogen that passed downstream from the electrolysis unit into several storage vessels. Hydrogen-oxygen mixtures are very hazardous. Subsequent …
Last Updated Thu, 06/26/2025 - 17:04
FAQ
… Library: White_Paper-Qualified_Individuals_for_Liquid_Hydrogen   Similar qualifications for vent system design include: A “qualified” individual for liquid hydrogen should be qualified in all aspects of vent systems, … … 864 … 958 … When discussing design considerations, it was rightly noted the need for a qualified person to do the …
Last Updated Thu, 07/03/2025 - 14:36
FAQ
Hydrogen flames can be nearly invisible in daylight, … especially at low flowrates. The concentration of hydrogen does not have much effect on the color of the flame. Many hydrogen incidents or fires will have a bright orange hue, or …
Last Updated Mon, 06/30/2025 - 16:01
FAQ
… Understand any reactions the hydrogen can add to what is being vented. For instance, O2/H2 … parameters of the streams to ensure no back flow into the hydrogen system or vice versa. Ensure the venting/flaring system can handle the hydrogen flow parameters. … 894 … 914 … In a plant where …
Last Updated Mon, 06/30/2025 - 16:13
FAQ
… Low-pressure vents at mostly low hydrogen purity are not as large safety risk as high-pressure pure hydrogen vents. These vents should still go to a vent stack, … the reaction forces of the flow exiting and the hydrogen cloud should be modeled based on NFPA 2 to ensure …
Last Updated Thu, 07/03/2025 - 14:44
FAQ
… frozen air (which contains oxygen) has built up within a hydrogen process or vent system. These incidents with vent … cold and allows air into the system in contact with a cold hydrogen stream.  Vent systems are at risk since they are … might result in the aspiration of air into a cold hydrogen flow which then leads to the freezing of the air.  A …
Last Updated Mon, 06/30/2025 - 16:16
FAQ
… A release is defined by the amount of hydrogen, the rate of hydrogen flow, vent location (indoors or outdoors), geometry … could be defined as a release that keeps the flammable hydrogen cloud from damaging its surroundings.  … 867 … 894 … …
Last Updated Thu, 06/06/2024 - 23:54
HyARC Data Page
Last Updated Wed, 04/23/2025 - 18:36
Document Library
… of candidate metal hydrides being considered for hydrogen storage applications. A three-task research program …
Last Updated Thu, 06/19/2025 - 15:49
FAQ
… condition for vent stacks is to always assume that the hydrogen will ignite. The stack musts be designed such that … radiation to surrounding personnel and exposures. Although hydrogen fires have comparatively low radiation compared to … Also, the temperature of the flame is very high, so if the hydrogen flame contacts materials around the vent stack, they …
Last Updated Thu, 06/19/2025 - 16:02
FAQ
… Catalytic recombiners are effective at preventing flammable hydrogen mixtures and also sometimes useful to monitor hydrogen concentrations through heat evolution when an … can be catalytically converted, above which combustible hydrogen mixtures are still possible. In a fully enclosed …
Last Updated Mon, 06/30/2025 - 16:09
FAQ
… Delayed ignition is a significant hazard for hydrogen releases, either intended or unintended. The primary … vapor cloud which could contain a significant quantity of hydrogen. The H2Tools Incidents database contains a number of …
Last Updated Fri, 10/18/2024 - 20:32
Fuel Cell Codes and Standards
… streams. It specifically applies to large volume hydrogen production plants, defined for this publication as a … the publication is left to the reader. … The 1st edition was published in 2016, and is available at www.cganet.org … …
Last Updated Mon, 08/05/2024 - 23:47
Team
… has conducted in-depth research on topics related to hydrogen safety, including deflagration venting, vapor cloud …
Last Updated Mon, 08/05/2024 - 23:43
Team
… own consulting firm to advance the safe implementation of hydrogen fuel cell and supply chain technologies.   … Rick …
Last Updated Tue, 07/29/2025 - 21:17
AWST Protocol
… The increasing demand for efficient and sustainable hydrogen production has driven significant advancements in …
Last Updated Tue, 06/17/2025 - 19:27
FAQ
… pressure (if any) for leak checking newly assembled hydrogen piping systems? It is unclear what pressure is … how does it apply to other types of connections from hydrogen fueling stations like double ferrule compression …
Last Updated Wed, 10/16/2024 - 18:43
Fuel Cell Codes and Standards
… and maintenance of site-built and modular gaseous hydrogen fueling stations (HFS) for light duty vehicles, … as a CSA standard in April 2016. The second edition was published in March 2020.  Initiating revision to …
Last Updated Thu, 06/26/2025 - 16:33
FAQ
… to the incident where a fire occurred and the vent system was damaged, then this may have been due to lack of proper … is not required. The rupture disc is not supposed to vent hydrogen unless the cylinder is engulfed in a fire both … required to maintain cylinder integrity. Although adding hydrogen to a fire is not a perfect solution, it is better …
We are professional and reliable provider since we offer customers the most powerful and beautiful themes. Besides, we always catch the latest technology and adapt to follow world’s new trends to deliver the best themes to the market.

Contact info

We are the leaders in the building industries and factories. We're word wide. We never give up on the challenges.

Recent Posts