Skip to main content
The search found 1530 results
Last Updated Thu, 07/03/2025 - 15:21
FAQ
… If the concentration of hydrogen is less than the Lower Flammability Limit (LFL) of … This mixture can also be used in conjunction with a hydrogen detector for leak testing gaseous hydrogen equipment. … 845 … 795 … 1022 … 832 … 2063 … Is …
Last Updated Wed, 06/18/2025 - 17:03
FAQ
… but also misleading in quantifying the dispersion of hydrogen in terms of comparison of diffusion of air in air. Hydrogen diffuses 4X faster than air, and the rate of mixing … However, it’s generically safe to say that an initial hydrogen gas cloud outdoors and unconfined will dissipate …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… ended 73 seconds after the launch in an explosive burn of hydrogen and oxygen propellants that destroyed the External … on the external tank which eventually failed, after which liquid hydrogen and liquid oxygen burnt in an explosive combustion. There is …
Last Updated Wed, 04/23/2025 - 20:19
Document Library
… The information presented is intended as a reference to hydrogen design and practice and not as an authorizing … or that which is advised but not mandatory. Guidelines for Hydrogen System Design, Materials Selection, Operations, … Storage, and Transportation. … Safety Standard for Hydrogen and Hydrogen Systems …
Last Updated Tue, 07/15/2025 - 14:58
FAQ
… atmospheric pressure where the autoignition temperature of hydrogen is 585°C.  … 864 … 770 … 814 … We are working on a project using hydrogen at 600 kPa (87 psi). How is the auto-ignition temperature of hydrogen as a function of pressure determined? … Hydrogen
Last Updated Mon, 07/14/2025 - 15:52
FAQ
… courses. These, along with a general overview of hydrogen, would probably suffice until work begins on systems … in these activities. … 2117 … How can I implement a hydrogen safety training program in a company where hydrogen is part of the future but not currently used or …
Last Updated Wed, 07/16/2025 - 14:59
FAQ
… This production rate of hydrogen of about 96 kg/h is quite significant, which … from this production rate in order to determine how much hydrogen ground storage is needed. Since the project is in … vessels that might be optimized to store the quantity of hydrogen needed. Storage vessel cost may range from $500 up …
Last Updated Wed, 06/18/2025 - 16:49
FAQ
… The HSP discourages the use of this type of piping for hydrogen despite the low likelihood of ignition within the … produce an electrostatic discharge. Since the nominal hydrogen concentration is so high (and assuming the purge-in … exit if the polyethylene film extends to the exit. If the hydrogen is flowing into an air atmosphere, an electrostatic …
Last Updated Tue, 07/15/2025 - 16:03
FAQ
… published research on the effect of water sprays on hydrogen deflagrations and deflagration-to-detonation … et al. (Atomics International report, 1973) described hydrogen detonation tube testing with and without a … spray. They found the water spray prevented detonations at hydrogen concentrations of 20% to 24%, but not at 28%. Drop …
Last Updated Mon, 07/14/2025 - 15:58
FAQ
… Flammable hydrogen releases can result in deflagration and transition … depends on numerous parameters such as cloud size, hydrogen concentration, confinement, and congestion. Releases … to detonation. … 796 … 792 … 2116 … Will a flammable hydrogen/air cloud detonate? If so, under what conditions? … …
Last Updated Thu, 06/19/2025 - 14:44
FAQ
… 521 (Section 5.2.1), which can be argued is the case with hydrogen for typical industrial gas applications. Flares are … there codes or standards addressing the installation of a hydrogen flare system for excess hydrogen production. Some API and NASA documents address …
Last Updated Mon, 07/14/2025 - 14:42
FAQ
… In most cases, it is not necessary to depressurize hydrogen systems in an emergency. Pressure vessels are … analysis. … 1013 … Must a pressure vessel containing hydrogen be depressurized in an emergency? … Depressurization of hydrogen pressure vessels …
Last Updated Tue, 07/15/2025 - 15:07
FAQ
… answer without greater understanding of the quantities of hydrogen involved, the types of vessels involved, and the … If a tank instantaneously ruptures and completely releases hydrogen into the atmosphere, how long does it take to … a point where it is no longer a fire or explosion risk? … Hydrogen Tank Rupture …
Last Updated Mon, 07/07/2025 - 16:29
FAQ
Hydrogen affects the mechanical properties of most materials. For example, hydrogen reduces the fracture toughness and increases the … be revealed as requirements in codes like ASME B31.12, Hydrogen Piping and Pipelines, and ASME B31.8, Gas …
Last Updated Wed, 07/09/2025 - 15:35
FAQ
Hydrogen has been used as a fuel to operate cars, buses, … significant barriers that would prevent the application of hydrogen for trains for a properly designed system. … 1036 … … or safety barriers that are applicable to the operation of hydrogen trains? … Hydrogen train safety considerations …
Last Updated Thu, 05/02/2024 - 20:22
Video
… This video explains some of hydrogen's unique properties and compares hydrogen and propane flames. … Characteristics of Hydrogen
Last Updated Tue, 01/28/2025 - 15:55
Fuel Cell Codes and Standards
… This standard provides glossary and definitions of hydrogen, hydrogen and hydrogen energy systems technology and its application. … …
Last Updated Mon, 07/14/2025 - 15:11
FAQ
… to clear personnel from the immediate area, isolate the hydrogen, shut down the equipment, contact local responders, … … 1013 … What are the emergency response procedures for a hydrogen-related incident? … Hydrogen emergency response procedures …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… and a catalyst: palladium. The operator was performing hydrogen purges, consisting in sending hydrogen under pressure into the reactor via the hydrogen … the introduction of this new practice, the presence of liquid in the system avoided the drying of the catalyst and …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… closed down the system as follows: - he shut off the hydrogen addition at the reactor and closed the valve at the hydrogen cylinder bank; - the reactor's agitator was turned … was left isolated with an hydrogen atmosphere over the liquid. No nitrogen inerting was used. The operator checked …
We are professional and reliable provider since we offer customers the most powerful and beautiful themes. Besides, we always catch the latest technology and adapt to follow world’s new trends to deliver the best themes to the market.

Contact info

We are the leaders in the building industries and factories. We're word wide. We never give up on the challenges.