Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… Leaking hydrogen ignited a fire that burned several hours at an oil …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… Fire due to hydrogen gas leakage from a cadre falling in transportation. …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… Explosion at chemical plant in Akita Prefecture involving hydrogen killed a worker … Explosion in Chemical Plant (49) …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… The vent occurred at the hydrogen manufacturing unit: a pipe of this unit burst, … explosion occurred while checking the temperature in the hydrogen manufacturing device after pouring liquefied butane …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… car rolled down the road without driver and hit the hydrogen bus. … Collision with a Car (412) …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… The explosion occurred in the ammonia/hydrogen separator of the ammonia reactor due to …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… exchanger failed at the flange. Recycled gas, primarily hydrogen, was suddenly released when the pipe broke away. The hydrogen, under high pressure and temperature, was ignited, … along that fire path. Initial information indicated the hydrogen was pressurized at approximately 3,000 pounds per …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… A fire broke out following a hydrogen leak on the cyclododecane unit in a chemical plant. … corrosion under the thermal insulation layer. It caused a hydrogen leak and a flow of cyclododecane. The released hydrogen auto-ignited and the fire spread to the …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… earth fault). The stator earth fault had damaged two hydrogen cooler tubes, which allowed hydrogen to pass from the stator casing into the condenser …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… hydrochloric acid was made to react with zinc to generate hydrogen, at a junior high school. Injures were caused by … lightly injured pupils were sent to hospital. Probably hydrogen entered in contact with oxygen because of a wrong …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… explosion shad occurred which was taken to indicate that hydrogen concentration within the pot was not normally within … other conditions could provide sufficient energy to ignite hydrogen and air mixtures, and that elimination of the … The following possibilities were identified:1. Prevent hydrogen concentration from reaching the lower explosive …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… a refinery hydrocracker plant involving a gauge glass and hydrogen gas oil. … Fire at a Refinery Hydrocracker (545) …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… fire started in the refinery's hydrocracking unit at the hydrogen compressor of re refinery (India). … Fire in the …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… at the 90 elbow of a pressure pipe containing a mixture of hydrogen and naphtha. This pipe was located between the …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… plant storage area containing ammonia, acetone, and hydrogen. … Explosion at a Storage Area of a Chemical Plant …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… used thermal imaging cameras to locate and extinguish a hydrogen fire at a silicon manufacturing plant. … Fire in a …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… An explosion followed by fire occurred in the hydrogen filling unit of chemical plant for the production of …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… phosphor pentoxide with wine leads to phosphoric acid and hydrogen … Continuous Release in Partially Confined …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… by the unexpected presence of a considerable amount of hydrogen in the tank. According tot the eMARS and ARIA report (see references) , the hydrogen was formed in a reaction of metal powder traces and … vessel, the reaction continued, producing small amounts of hydrogen, which accumulated in the top. When the piping on …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… a compressor and high pressure tanks, used to refuel hydrogen buses. A nitrogen line used for purging was apparently left open so that N2 was flowing into the hydrogen tank svia the compressor.Because only oxygen is …