Skip to main content
The search found 1568 results
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… A truckload of hydrogen cylinders caught fire at plant producing artificial sweetener. … Fire on Truck Carrying Hydrogen Cylinders (170) …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… A road transportation incident. A road tanker of hydrogen overturned and caught fire. … Fire from Hydrogen Road Tanker (586) …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… flare reduced the leak flow rapidly. At 10:12 am, the fire was extinguished. 15,7 t of hydrocarbons were sent to … outside. The leak involved naphtha, hydrocarbon gases and hydrogen. Due to the thermal effects of the ignited leak, … were damaged.[ARIA event 58577] … Hydrocarbons and Hydrogen Fire in a Refinery (1024) …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… A leak occurred while loading a semi-trailer carrying hydrogen gas cylinders. An employee closed the supply valve … and reached the trailer's tires. The vehicle caught fire, causing a plume of black smoke visible from a distance. … unit to study how to empty the trailers from the remaining hydrogen and to purge them. (ARIA database) … Hydrogen Fire
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… A hydrogen generator overheated during testing and started a small fire in a power plant. … Fire on a Hydrogen Generator in a Power Plant (166) …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… A hydrogen leak occurred on the hydrogen line of a hydro-desulfurization unit, followed by … resulted from the dynamic load applied to the line. … Hydrogen Fire in a Refinery (958) …
Last Updated Thu, 01/15/2015 - 23:22
Lesson Learned
Hydrogen Fire at a Hydrogen Storage Facility …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… A lorry loaded with gaseous hydrogen cylinders caught fire and shut a motorway.No one has been injured. … Hydrogen Fire from a Tube Trailer (1010) …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… A fire occurred on a plant. The fire resulted from an escape of liquid hydrogen from a joint between an isolating block valve and a … in the section of the plant. … Fire from a Liquid Hydrogen Pipe (579) …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
Fire due to hydrogen gas leakage from a cadre falling in transportation. … Fire (596) …
Last Updated Fri, 02/21/2025 - 22:57
Lesson Learned
Hydrogen Plant Explosion and Fire
Last Updated Thu, 01/15/2015 - 20:07
Lesson Learned
Hydrogen Cylinder Fire in Laboratory …
Last Updated Thu, 01/15/2015 - 17:44
Lesson Learned
Fire at Hydrogen Fueling Station …
Last Updated Fri, 01/16/2015 - 17:32
Lesson Learned
Hydrogen Fire in a Storage Vessel …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… a power generator during the shutdown of one reactor unit. Hydrogen leaked from the cooling circuit of the generator due to damaged sealing. The hydrogen ignited. The fire was extinguished after 1 hour 40 minutes. … Hydrogen
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… The fire occurred on the tube plate gaskets of 3 of the 4 … and p=30 bar) was a mixture of 30% hydrocarbons and 70% hydrogen. After depressurisation of the unit and nitrogen … surfaces were poorly prepared. … Fire of a Mixture of Hydrogen and Hydrocarbons in a Refinery (895) …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… The fire occurred on a flange of a hydrogen supply line to a … and downstream valves , and shutting down the reactor. … Hydrogen Fire in the Desulfurization Unit of a Refinery (923) …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… The fire occurred after a hydrogen released from a venting valve opened for inspection. The hydrogen was at 300 bar and 300C centigrade. The hydrogen
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
Fire in an ammonia plantA fire broke out in the hydrogen section of ammonia plant. … Fire in Hydrogen Section of Ammonia Plant" (674) …
Last Updated Fri, 04/18/2025 - 19:40
HIAD Event
… A fire was sparked by a hydrogen leak at a Goodrich plant … 9:50 a.m. Friday, safety officials said. "Apparently the hydrogen caused a fire when it hit the air," said Chief Alex …