Near Miss: Hydrogen Detector Triggers Alarm at Airport Refueling Station (1064)

This near miss occurred at the at an airport's hydrogen refilling station. Around 4:30 a.m., the hydrogen detector of the station was triggered and a sound and light alarm were activated. The hydrogen filling station was up in safe mode and the hydrogen storage system isolated. The connection pipes were purged via the vent and the power supply cut off. An on-call technician from the company in charge of managing the station arrived at 6:15 a.m., confirmed that the installation has been made safe and stopped the alarm. The leak was located on the compressors filter.

Near Miss: Hydrogen Leak at Airport Refueling Station Causes Emergency Response (1063)

This near miss occurred at an airport's hydrogen refilling station. At 7:35, a hydrogen leak was detected by hearing whistles in the near of a pipe. The operators warned the airport firefighters ten minutes later. Upon their arrival, the firefighters set up a security perimeter of 150 m around the installation. The station is located on the border between the public space and the private space and was surrounded by a fence with a gate accessible only by a code unknown to the emergency services.

Leakage at a Hydrogen Buses Refilling Station (1062)

This near miss occurred at a depot site with 20 fuel cell buses are operated by a local bus company. A hissing sound was heard coming from a hydrogen tank at the refuelling facility, and the local fire department was alerted.After roughly two hours, the fire brigade managed to close the main hydrogen supply, temporarily solving the problem, and local buses were able to resume their service, but were not able refill their H2 cylinders.

Dispenser Nozzle Freezing During Hydrogen Refueling (1038)

This entry refer to a series of events occurred before the date given, which corresponds to the publication of the evidences at the Int. Conference on Hydrogen Safety 2015. The nozzle/receptacle connection froze when refuelling the on-board hydrogen storage system at the lowest precooling temperature of -40 C. However, freezing did not cause apparatus damage nor hydrogen leakage. The nozzle/receptacle is thus able to fuel safely even if the nozzle/receptacle is stuck due to ice.

Hydrogen Release at a Public Hydrogen Refueling Station (953)

The station was storing 6,000 litres of liquid hydrogen in ten tanks. Rescue services were alerted and the station's activity is interrupted. The leak was stopped by closing the valves. According to the H2Tools report (see references), a vehicle fill had depleted the high-pressure hydrogen inventory. Consequently, the compressor turned on to refill the storage by compressing 4 bar (60 psig) hydrogen from a liquid hydrogen tank up to the 380 bar (5500 psig) compressed storage tank. After running about 2 hours, a crankshaft bearing started to fail.

Release at a Dispenser of a Hrs (463)

Minor leak in the break-away coupling for 35MPa dispenser of a refuelling station for buses.The leak developed in the break-away coupling during a controlled test refuel. The test was attended by the station operators staff. The leak occurred as the temperature was decreasing (the hydrogen is pre-chilled to between -33oC and -40oC prior to entering the dispenser).The dispenser was taken out of service until a replacement break-away coupling was installed by the manufacturer.

Damage of a Hrs Canopy (454)

The HRS canopy was lower than the forecourt canopy. heavy duty vehicles were not noticing the issue and hitting the HRS canopy assuming same height.The canopy has now been repaired twice, and the HRS operator will take care to raise its height to avoid the repeating of the collision. No injury or harm to people was caused.

Dispenser Failure (403)

One of the two dispensers at a refuelling station for buses shutdown at a refuelling station. The dispenser company were called and confirmed there was an issue with the dispenser. The station operator switched to the second dispenser. Fuelling was not interrupted.
Subscribe to Hydrogen Refueling Station
We are professional and reliable provider since we offer customers the most powerful and beautiful themes. Besides, we always catch the latest technology and adapt to follow world’s new trends to deliver the best themes to the market.

Contact info

We are the leaders in the building industries and factories. We're word wide. We never give up on the challenges.

Recent Posts