The leak occurred on a process pipe of a pressurized at 17 bar and located 3.5 m from the ground The gaseous mixture composed of hydrogen, methane and hydrogen sulfide (density: 0.6) was released to…
At least one person was injured in an explosion at a theatre building. The investigation concluded that the accident has been caused by hydrogen entering the sprinkler room from the sprinkler piping…
Leaking hydrogen ignited at a plant that processes bitumen from oil sands.
A fire started on the brakes of a truck carrying hydrogen. Due to the risk of extension of the fire to the hydrogen, the fire brigade install an emergency area until the fire is extinguished.There…
Electric spark ignited hydrogen in a captive advertising balloon.
Plant own emergency response team was activated, assisted from local fire and emergency Services and regional Police. No one was injured during the incident and flames were brought under control…
A fire in an oil refineryThe fire broke out together with an explosion noise from the heavy oil direct desulfurization system of the height of about 20 m. The fire burned a part of the system…
A case under negligent act causing life danger was booked against the absconding balloon seller, Panic gripped the locality, bomb disposal squads, sniffer dogs and clues teams were rushed to the spot…
In a residual-oil hydrotreatment unit (also called residual oil hydrogenation) plant, a hydrogenation unit caught fire with a huge bang, followed by a fireball in the form of a mushroom cloud. Black…
A 7 inch thick reactor of a wide range hydrocracking unit being operated by computer at 2500 psi failed explosively due to localised heating. The blast caused widespread damage over a 300 yard radius…
An explosion of unknown cause occurred at a hydrogen manufacturing plant. The explosion occurred on the second floor of the building, used by employees as a cafeteria and offices. The company where…
Hydrogen gas explosion blew the lid off a heavy container at a heat treatment and brazing plant, crushing one workers hand.
One employee was injured in an explosion in a chemical plant storage area containing ammonia, acetone, and hydrogen.
The explosion was followed by a fire. Eyewitnesses reported seeing a "huge gush of fire". The local fire and rescue team brought the fire under control.According to the company, the explosion was…
An explosion at a refinery started a fire that was fueled by diesel and hydrogen.
At around 5.45 am, an explosion occurred at an oil refining plant. The operating units of the hydrogen compressors are stopped. Around 8:45, firefighters master the fire. 11 people are taken to…
Explosion at hydrogen unit operated workers evacuated, 2 injured, community rattled.
An hydrogen explosion occurred within the off-gas system, causing the stop of the sump pump; subsequently both trains of the standby gas treatment system were declared inoperable. The sump is part of…
Explosion of nitrobenzene fluoride while mixing with hydrogen gas: Fluoronitrobenzene exploded when mixing it with compressed hydrogen gas.
The incident occurred at company producing specialised products for aerospace and aeropwer applications. An employee was operating an induction brazing machine under hydrogen atmosphere when an…