Skip to main content

Post Test Teardown Analysis

Author(s)
Jennifer Glenn
Keywords
Proton Exchange Membrane (PEM)
Anion Exchange Membrane (AEM)
Catalyst Coated Membrane (CCM)
Gas Diffusion Layer (GDL)
Porous Transport Layer (PTL)
Abstract

This procedure is intended to provide guidance and best practices for diagnosing component failure in an operated electrolyzer cell for both PEM and AEM systems. Instructions for disassembling cell hardware, labeling and preserving cell components and diagnostic test methods for these components are discussed. This procedure assumes a 1-cell Fraunhofer electrolyzer test cell, but it is possible to adapt this for other cell hardware and multi-cell stacks. The SOP was developed by Jennifer Glenn.

AWST Technology
Low Temperature Electrolysis (LTE)
Protocol #
LTE-P-21