Skip to main content

Alkaline Stability of AEMs

Author(s)
Vijay Ramani
Kelly M. Meek
Keywords
Chemical Stability
Anion Exchange Membrane (AEM)
Ionic Conductivity
Abstract

A procedure for ex-situ evaluation of chemical (alkaline) stability of anion exchange membranes (AEM). The IEC and ionic conductivity of an AEM is measured before and after being heated (typically at 80C in 1 M KOH) for ~1000 hours. The SOP was prepared by Vijay Ramani and Kelly M. Meek.

AWST Technology
Low Temperature Electrolysis (LTE)
Protocol #
LTE-P-22
Webform