Skip to main content

AEM Conductivity

Author(s)
Yushan Yan
Santiago Rojas-Carbonell
Brian Setzler
Matthew Ueckermann
Kelly Meek
Keywords
Electrolyzer
Anion Exchange Membrane (AEM)
Conductivity
Abstract

A procedure for measuring the hydroxide conductivity of an anion exchange membrane (AEM). A four-electrode In-plane conductivity is measured as a function of relative humidity (RH). The SOP was prepared by Yushan Yan, Santiago Rojas-Carbonell, Brian Setzler, Matthew Ueckermann, Kelly Meek.

AWST Technology
Low Temperature Electrolysis (LTE)
Protocol #
LTE-P-6