An accident occurred during setup for a popular hydrogen-oxygen balloon science demonstration at a local public school. The demonstrator suffered painful second-degree burns to his right forearm and was taken to the hospital. The paramedics feared that grave respiratory damage (due to flame inhalation) might have occurred.

The demonstrator had transported 15 helium-quality balloons, pre-filled with a hydrogen-oxygen mixture, in a large, black, polyethylene garbage bag. During the setup, he opened the bag to remove a single balloon for stringing and floating. Without warning, the entire bag of balloons detonated violently. Fortunately, the incident occurred an hour prior to the program and no one else was near. It was also fortunate that only a small box caught fire and none of view more

During the early morning hours on a Tuesday, a university support staff member was preparing for an off-campus community outreach program for high-school-age students in the community. One of the program demonstrations was to show students the reaction energy and properties of the hydrogen + oxygen = water chemical reaction. It was a demonstration that the professor and the staff member overseeing the program had done for over 15 years with no incidents ever occurring.

To prepare for the demonstration, eight balloons were filled, four with pure hydrogen and four with the proper combination of hydrogen and oxygen. The balloons were placed into a larger plastic garbage bag and carried outside to a university-owned SUV located next to the building's loading dock. The bag of view more

A fatal accident took place at an onshore processing facility for slop water from the offshore petroleum industry.

Drilling fluids, or mud, are typically oil-water emulsions consisting of base oil (continuous phase), water (dispersed phase), and emulsifying agents. Used drilling mud, or slop, is mud enriched with water and rock cuttings from drilling --- typically 60-80% water, 10-20% emulated base oil, and 10-20% rock cuttings. The used drilling fluids are collected in slop tanks on oil platforms and later shipped to onshore facilities for further processing.

On the day of the accident, two operators were trying to remove the lid from a manhole on top of a 1600-cubic meter storage tank. However, they were not able to unscrew the rusted bolts holding the lid in place, and view more