Scope

This test method covers an electronic hydrogen detection instrument procedure for measurement of plating permeability to hydrogen. This method measures a variable related to hydrogen absorbed by steel during plating and to the hydrogen permeability of the plate during post plating baking. A specific application of this method is controlling cadmium-plating processes in which the plate porosity relative to hydrogen is critical, such as cadmium on high-strength steel.

Status
Published
Status Explanation

The 2018 edition is available from www.astm.org.

Proposed revision, WK 74454, will gather existing and generate new ISL vs SL data with the goal of increasing the utilization of ISL as an option to SL in F519.